6. Electrical work
1
C
B
A
2
ON
STAND
COOL HEAT
OFF
BY
Fig. 6-2
D
ON/OFF
MODE
CHECK
TEST RUN
SET
1,4
Fig. 6-4
1
CHECK
ON/OFF
TEMP
E
3
C,D
FAN
AUTO STOP
MODE
VANE
AUTO START
CHECK
LOUVER
h
F
A
TEST RUN
min
B
SET
RESET
CLOCK
Fig. 6-5
MODEL SELECT
A
ON/OFF
TEMP
3
FAN
AUTO STOP
MODE
VANE
AUTO START
CHECK
LOUVER
h
TEST RUN
min
2,4
SET
RESET
CLOCK
Fig. 6-3
A
MODEL SELECT
TEMP
3
FAN
AUTO STOP
VANE
AUTO START
LOUVER
h
min
2
RESET
CLOCK
2
CHECK
CHECK
4
CHECK
CHECK
6-2 Installing the wireless remote controller
1) Installation area
• Area in which the remote controller is not exposed to direct sunshine.
• Area in which there is no nearby heating source.
• Area in which the remote controller is not exposed to cold (or hot) winds.
• Area in which the remote controller can be operated easily.
• Area in which the remote controller is beyond the reach of children.
2) Installation method (Fig. 6-2)
1 Attach the remote controller holder to the desired location using two tapping screws.
2 Place the lower end of the controller into the holder.
A Remote controller
B Wall
C Display panel
D Receiver
• The signal can travel up to approximately 7 meters (in a straight line) within 45
degrees to both right and left of the center line of the receiver.
3) Setting (Fig. 6-3)
1 Insert batteries.
2 Press the SET button with something sharp at the end.
blinks and Model No. is lighted.
MODEL SELECT
3 Press the temp
button to set the Model No.
4 Press the SET button with something sharp at the end.
and Model No. are lighted for three seconds, then turned off.
MODEL SELECT
Indoor
PLH, PCH, PKH-P·GAH
PLA, PCA, PKA-P·GA
PKH-P·FAH
PKA-P·FA, PKA-RP·FA
4) Assigning a remote controller to each unit (Fig. 6-4)
Each unit can be operated only by the assigned remote controller.
Make sure each pair of an indoor unit PC board and a remote controller is assigned
to the same pair No.
5) Wireless remote controller pair number setting operation
1 Press the SET button with something sharp at the end.
Start this operation from the status of remote controller display turned off.
blinks and Model No. is lighted.
MODEL SELECT
min
2 Press the
button twice continuously.
Pair No. "0" blinks.
3 Press the temp
button to set the pair number you want to set.
4 Press the SET button with something sharp at the end.
Set pair number is lighted for three seconds then turned off.
A Pair No. of wireless remote controller
0
1
2
3~9
6.3. Function Settings (Fig. 6-5)
Changing the power voltage setting
Be sure to change the power voltage setting depending on the voltage used.
1 Go to the function select mode
CHECK
button F twice continuously.
Press the
(Start this operation from the status of remote controller display turned off.)
is lighted and "00" blinks.
CHECK
button C once to set "50". Direct the wireless remote controller
Press the temp
toward the receiver of the indoor unit and press the
2 Setting the unit number
button C and D to set the unit number "00". Direct the wireless
Press the temp
remote controller toward the receiver of the indoor unit and press the
3 Selecting a mode
Enter 04 to change the power voltage setting using the
Direct the wireless remote controller toward the receiver of the indoor unit and press
h
button A.
the
Current setting number:
1 = 1 beep (one second)
2 = 2 beeps (one second each)
3 = 3 beeps (one second each)
4 Selecting the setting number
C and
D buttons to change the power voltage setting to 01 (240 V).
Use the
Direct the wireless remote controller toward the sensor of the indoor unit and press
h
button A.
the
5 To select multiple functions continuously
Repeat steps 3 and 4 to change multiple function settings continuously.
6 Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit and press
button E.
the
Note:
Whenever changes are made to the function settings after construction or
maintenance, be sure to record the added functions with an " ", in the "Check"
column provided on the chart.
A Model No.
Outdoor
PUH
001
PUH, PUHZ
001
PU
033
PUH
003
PUH, PUHZ
003
PU
035
Indoor PC board
Factory setting
Cut J41
Cut J42
Cut J41, J42
h
button A.
min
button B.
C and
D buttons.
7