6. Grasp the starter grip (Figure 11) and slowly pull it out. The
resistance becomes the hardest at a certain position, corre-
sponding to the compression point. Pull the starter grip briskly
and smoothly for starting.
Figure 11. Starter Grip
7. If the engine has started, slowly return the choke lever
(Figure 12 ) to the CLOSED position. If the engine has not
started repeat steps 1 through 6.
Figure 12. Choke Lever (Closed)
8. Before the pump is placed into operation, run the engine for
several minutes. Check for fuel leaks, and noises that would
associate with a lose component.
9. To begin pumping, place the throttle lever (Figure 13) in the
" RUN "position.
Figure 13. Throttle Lever (Run)
PAGE 18 — QP-305SLT CENTRIFUGAL PUMP — OPERATION & PARTS MANUAL — REV. #0 (03/22/05)
QP-305SLT — INITIAL START-UP (ENGINE)
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
ALWAYS run engine at full speed while pumping.
Stopping The Engine
Normal Shutdown
1. Move the throttle lever to the IDLE position (Figure 14) and
run the engine for three minutes at low speed.
2. After the engine cools , turn the engine ON/OFF switch to the
"OFF" position (Figure 15).
Figure 15. Engine ON/OFF Switch (OFF)
3. Place the fuel shut-off lever (Figure 16) in the OFF
position.
Emergency Showdown
1. Move the throttle lever quickly to the IDLE position, and place
the engine ON/OFF switch in the OFF position.
Figure 14. Throttle Lever (Idle)
Figure 16. Fuel Valve Lever (OFF)