Bosch GWH 2400 ES NG Manual page 33

Temperature modulated with electronic ignition suitable for heating potable water only not approved for space heating purposes
Hide thumbs Also See for GWH 2400 ES NG:
Table of Contents

Advertisement

CO
max. input
P1
min. input
P2
max. input
P1
min. input
P2
* Values above are for climate controlled conditions.
Inputs such as gas pressure, heating value of the gas,
humidity and temperature of combustion air all impact CO
and CO
values. Changes in these inputs can result in
2
different CO and CO
values on the same appliance.
2
Table 16 CO
& CO target numbers
2
Final Readings
P2 CO
Reading:
2
P1 CO
Reading:
2
Fig. 57 Adjusting P1 CO
Fig. 58 Adjusting P2 CO
6 720 608 782
Max. CO
range (%)
level
2
(measured)
Nat. Gas
6.9 % - 7.5 %
< 250 ppm
2.3 % - 2.6 %
< 60 ppm
LP Gas
8.1 % - 8.7 %
< 250 ppm
2.5 % - 2.8 %
< 60 ppm
% CO
2
% CO
2
level
2
6720608158-38.1AL
level
2
Maintenance and service
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents