Battery Fluid Level (Conventional Battery)

A poorly maintained battery will deteriorate rapidly. Check the
battery fluid level often. Maintain the fluid level between the
upper and lower level marks.
Upper Level
Add only distilled water. Tap water contains minerals that are
harmful to a battery.

Battery Removal

1.
Open the Hood.
2.
Remove the battery vent tube from the battery.
3.
Disconnect the black (negative) battery cable.
4.
Disconnect the red (positive) battery cable.
5.
Lift the battery out of the vehicle, being careful not to tip
it sideways and spill any electrolyte.
CAUTION
To reduce the chance of sparks: Whenever
removing the battery, disconnect the negative
(black) cable first. When reinstalling the battery,
install the negative cable last.

Battery Installation

Using a new battery that has not been fully charged can damage
the battery and result in a shorter life. It can also hinder vehicle
performance. Follow the battery charging procedure before
installing the battery.
1.
2.
3.
NOTE: The vent tube must be free of obstructions
and securely installed. Route the tube away from the
frame and vehicle body to prevent contact with
electrolyte.
Lower Level
4.
5.
6.
7.

Battery Storage

Whenever the vehicle is not used for a period of three months or
more, remove the battery from the vehicle, ensure that it's fully
charged, and store it out of the sun in a cool, dry place. Check
battery voltage each month during storage and recharge as
needed to maintain a full charge.
NOTE: Battery charge can be maintained by using a
Polaris battery tender charger or by charging about
once a month to make up for normal self-discharge.
Battery tenders can be left connected during the
storage period, and will automatically charge the
battery if the voltage drops below a pre-determined
point.

Battery Charging

1.
2.
3.
Ensure that the battery is fully charged.
Place the battery in the battery holder.
Install the battery vent tube.
Coat the terminals with dielectric grease or petroleum jelly.
Connect and tighten the red (positive) cable first.
Connect and tighten the black (negative) cable last.
Verify that cables are properly routed.
Remove the battery from the vehicle to prevent damage
from leaking or spilled electrolyte during charging.
Charge the battery with a charging output no larger than
1/10 of the battery's amp/hr rating. Charge as needed to
raise the specific gravity to 1.270 or greater.