Service Processor Error Codes - IBM TotalStorage NAS Gateway 500 Service Manual

Hide thumbs Also See for TotalStorage NAS Gateway 500:
Table of Contents

Advertisement

Service processor error codes

Attention:
Follow the procedure defined in the "Checkpoint and error code index" on page 127. If you
replace FRUs or perform an action and the problem is still not corrected, go to "MAP 1548: Processor
Subsystem Problem Isolation" on page 77 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" on page 45.
Note: Not all service processor error codes are supported.
Table 16. Service processor error codes
Error code Description
4064 0001 Scan interface basic assurance tests detected a
CEC backplane fault.
4064 0002 CEC backplane fault
4064 0003 Scan interface basic assurance tests detected
processor fault.
4064 0004 Processor fault
4064 000E Processor capacity card
4064 0010 DIMM fault
4064 0011 DIMM fault
4064 0012 DIMM fault
4064 0013 DIMM fault
4064 0014 DIMM fault
4064 0015 DIMM fault
4064 0016 DIMM fault
4064 0017 DIMM fault
4064 0018 DIMM fault
4064 0019 DIMM fault
4064 001A DIMM fault
4064 001B DIMM fault
4064 001C DIMM fault
154
NAS Gateway 500 Service Guide
Action or
possible failing FRU
CEC backplane
Location code: U0.1-P1
CEC backplane
Location code: U0.1-P1
Processor card
Location code: U0.1-P1-C1
Processor card
Location code: U0.1-P1-C2
Operator panel
Location code: U0.1-L1
DIMM
Location code: U0.1-P1-C1-M8
DIMM
Location code: U0.1-P1-C1-M6
DIMM
Location code: U0.1-P1-C1-M1
DIMM
Location code: U0.1-P1-C1-M3
DIMM
Location code: U0.1-P1-C1-M7
DIMM
Location code: U0.1-P1-C1-M5
DIMM
Location code: U0.1-P1-C1-M2
DIMM
Location code: U0.1-P1-C1-M4
DIMM
Location code: U0.1-P1-C2-M8
DIMM
Location code: U0.1-P1-C2-M6
DIMM
Location code: U0.1-P1-C2-M1
DIMM
Location code: U0.1-P1-C2-M3
DIMM
Location code: U0.1-P1-C2-M7

Advertisement

Table of Contents
loading

Table of Contents