Checking and acknowledging faults
Fault code
Const.
in the dis-
play
F1
X
F2
X
F3
X
Weat-
System
h.
character-
comp.
istics
X
Burner in
fault state
X
Burner in
fault state
X
Burner in
fault state
Troubleshooting
(cont.)
Cause
Remedy
Flue gas tempera-
Check the
ture limiter has
heating sys-
responded
tem water
level. Vent
the heating
system.
Press reset
E no sooner
than after
20 minutes.
Temperature limiter
Check the
has responded
heating sys-
tem water
level. Check
the circula-
tion pump.
Vent the heat-
ing system.
Check the
temperature
limiter and
leads.
Press E
The flame signal is
Check the
already present at
ionisation
burner start
electrode and
leads
Press E
81