Sanyo CLT-99 Service Manual page 7

Table of Contents

Advertisement

ADJUSTMENT
(TABLE -5.1)
STEP
CONDITION
CH
1. LINE MOD.
OSC OUTPUT
1kHz
4
(-20dBm)
300Hz
4
3kHz
4
2. DATA MOD.
PRESS "REDIAL/PAUSE"
4
2.3 RECEIVING
(See FIG -6, TABLE -6)
Test Equipment
• FM SSG (50 Ω OPEN TYPE)
AC Voltmeter (ACVM)
AC Adaptor (DC 12V ... Centre Minus)
Unit Condition
a) Disconnect the DC Power Supply.
b) Disconnect AF oscillator from TEL line, and connect AC voltmeter in parallel with distortion meter, terminated with 600 Ω during
load to the TEL line.
c) Disconnect linear detector from CN101 and connect FM SSG (1kHz, 2.5kHz dev., 49.830MHz, 46dBµV) to CN101.
d) Connect the DC power supply again, press "FLASH" & confirm current channel is at CH 6 (49.830MHz).
Slide S401 to "RINGER ON" (Rx MUTE will be OFF) & S402 to "PULSE".
e) Rx IF
.... Align T301 to obtain maximum deflection and minimum distortion from the read of AC voltmeter
and distortion meter respectively.
f) Rx RF
.... Change output level of FM SSG from 46dBµV to 5dBµV.
Align T101 & T102 to obtain minimum distortion at the distortion meter (less than 10%).
g) Rx AF LEVEL
.... Change output level of FM SSG from 5dBµV to 46dBµV.
Align VR301 to obtain -6dBm ± 1dBm from the read of AC voltmeter, and confirm at the FM
SSG input of
300Hz (46dBµV): the output of ACVM -12dBm ± 4dBm.
the output of ACVM -18dBm ± 4dBm.
3kHz (46dBµV):
h) CD Level Check
– Switch position S402
TONE ( Tx "OFF" ).
– Connect OSCILLOSCOPE to CD OUT.
– Confirm CD level is High
Low when FM SSG is 0
– Confirm CD level is High when FM SSG is 0
+2dBµ.
Adjustment
SSG
(FIG -6)
CN101 (H)
FM SSG
CN101 (E)
Mod. : 1kHz
Dev. : 2.5kHz
(TABLE -6)
STEP
CONDITION
CH
1. IF
SSG Output : 46dBµV
6
2. RF
SSG Output : 5dBµV
6
3. AF LEVEL
SSG : 46dBµV
(1kHz)
6
(300Hz)
6
(3kHz)
6
4. CD LEVEL
SSG Output : 0
+18dBµV
6
0
+2dBµV
CLT-99/SS (S/M) 6
7
ADJUST
ADJUSTED VALUE
SPECIFICATION
3.0V ± 0.15kHz dev.
VR601
3.0kHz dev.
2.2 ± 0.40kHz dev.
NONE
NONE
3.8 ± 0.60kHz dev.
NONE
NONE
5.0 ± 1.00kHz dev.
NONE
NONE
• Distortion Meter
• Dummy Load (600 Ω)
+24dBµ.
Unit
600 Ω
Loop
(TEL LINE)
Simulator
R
Power Supply
48VDC 50mA
ADJUST
ADJUSTED VALUE
SPECIFICATION
T301
Maximum Level
less than 5%
T101/T102
Minimum Distortion
less than 10%
-6dBm ± 1dB
VR301
-6dBm
-12dBm ± 4dB
NONE
NONE
-18dBm ± 4dB
NONE
NONE
NONE
NONE
CD OUT : High
NONE
NONE
CD OUT : High
-10-
ADJUSTMENT
PARTS LOCATION (BASE)
CN101
T101 (Rx, R)
T102 (Rx, R)
T103
(Rx, VCO)
Rx VCO
T201
(Tx, VCO)
T203
(Tx, POWER)
Tx VCO
VR601
(Tx MOD)
CN703
(SPEAKER)
CN702 (MIC)
S403
(SPEAKER
KEY)
TEST POINT (BASE)
6 ANT (H)
7 ANT (E)
# EXP. OUT
AC
Voltmeter
9 Rx VCO
8 COMP. OUT
! Tx VCO
Distortion
Meter
4 SPK (H)
5 SPK (E)
( CPT
Low
High
12/1/00, 3:17 PM
Rx MUTE ON
JIG SW
S001
~ DC 12V (–)
+ DC 12V (+)
- VCO GND
RINGER SW ON
TOGGLE SW
)
CPR
S002
~
JIG SW
SPEAKER KEY
GND
-11-
Rx MUTE
OFF
Tx POWER
ON
Tx POWER
OFF
VR301
(Rx LEVEL)
GND (VCO)
T301 (IF. R)
CD LEVEL
S404
(PAGE/INT
KEY)
RINGER SW ON
% AC
CHECK
1 TEST
$ CD LEVEL
2 MIC (H)
3 MIC (E)
& PAGE/INT.
KEY

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clt-99ss

Table of Contents