Installation - Harman XXV Freestanding Pellet Stove Installation & Operation Manual

Freestanding pellet stove
Hide thumbs Also See for XXV Freestanding Pellet Stove:
Table of Contents

Advertisement

Installing
Place the stove on a non-combustible floor protector that extends a minimum of 6 inches to the front (152mm), 6 inches
to the sides (152mm) and 0"(152mm) to the rear, which is flush with the rear of the hopper. Front and side floor protection
measurements are made from the firebox or window opening. Floor protection must also be positioned under horizontal flue
pipe, extending 2" (51mm) beyond each side of the pipe.
NOTE for Canadian installation only: Per ULC-S627-00, If installed on a combustible floor, the need to provide a
noncombustible floor protector covering the area beneath the space heater and extending at least 17.72" (450mm) on the
firing side and at least 7.87" (200mm) on the other sides.
In Canada, you may follow smaller U.S. floor protection requirements ONLY if the user agrees to completely shut-
down the appliance, and allow it to cool to where all fire is extinguished and the combustion blower and its indicator
light shuts off, prior to opening the firebox door or ash door.
The minimum floor protector material is 20 gauge sheet metal. Other floor protector materials are ceramic tile, stone, brick, etc.
Place the stove away from combustible walls at least as far as shown in Figures 2 and 3.
Note that the clearances shown are minimum for safety but do not leave much room for access when cleaning or servicing.
Please take this into account when placing the stove.
Floor Protection
Requirements
Sides
J
K
Front
L
Rear
Floor protector minimum: 40" X 40"
(1016mm X 1016mm)
NOTE: Measurement
"K" is measured from
the glass in the US
ONLY
J
USA
Floor Protection
Corner to edge dimension for corner installation floor protection.
45-7/8"
Floor Protection
3-90-00885R17_02/15

Installation

US
Canada
6"
200mm
6"
450mm
0"
200mm
L
J
K
Canada
Floor Protection
6.25"
159mm
Floor Protection
Alternate floor protector dimension may be used as long as
they satisfy the measurement requirements shown below.
Minumum size floor protection for a corner installation hearth
pad is 36" x 36". Clearance shown as 9" with optional side
shields installed.
3"/ 76mm
Fig. 3
6.25"
159mm
Fig. 2
XXV Pellet Stove
6