Napoleon ZCVF36 Installation And Operating Instructions Manual
Napoleon ZCVF36 Installation And Operating Instructions Manual

Napoleon ZCVF36 Installation And Operating Instructions Manual

Zero clearance ventless firebox enclosure
Hide thumbs Also See for ZCVF36:

Advertisement

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CONFORMS TO THE STANDARD ANSI Z21.91 VENTLESS FIREBOX ENCLOSURES FOR UNVENTED ROOM HEATERS
CERTIFIED FOR THE UNITED STATES USING ANSI METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
- This is an unvented gas-fi red heater that
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion
and ventilation air must be provided. Refer to
section " COMBUSTION AND VENTILATION AIR
PROVISIONS".
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
ZCVF36
ZCVF42
ZERO CLEARANCE
VENTLESS FIREBOX
ENCLOSURE
1.23A
W415-0527 / A / 04.14.11
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon ZCVF36

  • Page 1: Safety Information

    This appliance is not convertible for use with other gases. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com 1.23A...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS 2.1.1 ZCVF36 2.1.2 ZCVF42 GAS INLET LOCATIONS 2.2.1 ZCVF36 2.2.2 ZCVF42 GENERAL INSTRUCTIONS RATING PLATE INFORMATION FRAMING MINIMUM CLEARANCE TO COMBUSTIBLES 3.1.1 ZCVF36 3.1.2 ZCVF42 MINIMUM MANTEL CLEARANCES NAILING TAB INSTALLATION FINISHING HOOD INSTALLATION...
  • Page 3: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Under no circumstances should this appliance be modifi ed. •...
  • Page 4: Dimensions

    DIMENSIONS 2.1.1 ZCVF36 1 3/4” 42” 32 1/2” 25” 21 1/8” 19” 23” 31 7/8” 36” 2.1.2 ZCVF42 1 3/4” 46 5/8” 35 1/2” 30 ” 19” 21 1/8” 26” 40 1/2 ” 36 3/8” NOTE: Dashed lines represent the shape of the fi rebox walls and back...
  • Page 5: Gas Inlet Locations

    There are fi ve gas inlet locations on the ventless fi rebox enclosure. One on each side of the unit, two at the rear, and one on the bottom. Using the following illustrations identify the preferred inlet and remove corresponding knock out. 2.2.1 ZCVF36 16 3/8” 7”...
  • Page 6: General Instructions

    WALL OF FIREPLACE FIREPLACE FIREPLACE SIDES 4” TO MANTEL BACK 0” TOP WOLF STEEL LTD. MANTEL 4" 24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA 0” BACK 2” ” ” SERIAL NUMBER: ZCVF 0” BOTTOM BOTTOM W385-0318 / E FRONT...
  • Page 7: Framing

    COULD RESULT. THE APPLIANCE REQUIRES A MINIMUM ENCLOSURE HEIGHT. MEASURE FROM THE APPLIANCE BASE. IF STEEL STUD FRAMING KITS WITH CEMENT BOARD ARE PROVIDED, THEY MUST BE INSTALLED. 71.1 ZCVF36 ZCVF42 35 3/4" 32 3/4" W415-0527 / A / 04.14.11...
  • Page 8: Minimum Clearance To Combustibles

    Objects placed in front of the ventless fi rebox enclosure should be kept a minimum of 4 feet away from the front face. Minimum clearance to combustible construction from appliance: sides, back, bottom and top of the unit 0 inch recessed depth 21 1/4 inches 3.1.1 ZCVF36 OUTSIDE CHASE 21 1/4" 52 3/8” 42 1/2" 42 1/2”...
  • Page 9: Minimum Mantel Clearances

    MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 10: Finishing

    4.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. AS AN ALTERNATIVE, YOU CAN FINISH THE APPLIANCE WITH DRYWALL, SEE ILLUSTRATIONS TO FOLLOW.
  • Page 11: Optional Blower Installation

    5.0 OPTIONAL BLOWER INSTALLATION WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
  • Page 12 * Note: In either application it is necessary to remove the variable speed switch from the wiring har- ness and install into an electrical switch box as per electrical codes. WITH THERMAL SWITCH BRACKET Remove the hearth pads and the blower access cover.
  • Page 13: Replacements

    WITH THIS APPLIANCE MAY • Finish RESULT IN PROPERTY DAMAGE OR * IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR PERSONAL INJURY. FURTHER INFORMATION, CONTACT YOUR AUTHORIZED DEALER. 41.1 COMPONENTS ZCVF36 ZCVF42 DESCRIPTION W385-0334 W385-0334 NAPOLEON LOGO W565-0084 W565-0085 CURTAIN MESH...
  • Page 14: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON®...
  • Page 15: Service History

    8.0 SERVICE HISTORY 43.1 W415-0527 / A / 04.14.11...
  • Page 16 14.0 NOTES 44.1 W415-0527 / A / 04.14.11...

This manual is also suitable for:

Zcvf42

Table of Contents