3.6 Gas operation components
At the backside of the fridge the gas (safety) valve
and the burner control device is assembled,
which are operated with approx. 1.5V, controlled
by the electronics.
1 Burner Control Device P810
(igniter, flame control, flame safety device)
2 Gasvalve GV100
(gas sefety device, includes 2 serial mounted
valves; automatically closed at a
pressure > 1bar)
3 Gas connection below
4 Ignition electrode
5 Ionisation electrode
6 Ground
(Connection to burner control device)
The ionization control is used for flame recognition
in the burner chamber. The burner chassis serves
as earth contact.