Dometic RMT 7650 Service Instruction page 11

Absorption refrigerator + oven for recreation vehicles cool 3110
Hide thumbs Also See for RMT 7650:
Table of Contents

Advertisement

Installation
Terminal block MES RMT 7xx1 above
red:
+ cable 12 V heatingelement via ignition
operated relay and fuse 20A
white:
– cable 12 V heatingelement
violett:
+ cable 12 V permanent connection to
electronics
black:
– cable 12 V permanent connection to
electronics
D+ =
Input Dynamo+ from alternator
S+ =
Input control signal from solar charge
regulator
Terminal block AES RMT 7xx5 above
sw:
prepared D+ - cable
red:
+ cable 12 V heatingelement via ignition
operated relay and fuse 20A
white:
– cable 12 V heatingelement
violett:
+ cable 12 V permanent connection to
electronics
black:
– cable 12 V permanent connection to
electronics
Terminal block RMT 7xx1, RMT 7xx5 below
At the models RM76xx additional terminals are
assembled on the lower backside, seperated into
connetions "Electronics / D+" and "Heating ele-
ment".
Please note:
12V DC" means 12V connection to heating element via ignition operated relay. Do not
compare with "D+"- input signal of the alternator! "D+" and "S+" are different connec-
tions ( Do not exchange each other) !
black
violet
Fig. 1
sw
black
violet
Fig. 2
Fig. 3
11
4
red
white
red
white