Service Bulletin 4812 711 40310

AUTHOR: Robert Zimmermann
Last Update: 09/19/08
VERSION: 1.0
TITLE: Running change of capillary tube in production.
CAUSE
due to the fact that the Whirlpool cooling factories will implement step by step the
running change from copper capillary tube into aluminum capillary tube, it is
necessary for a service intervention to use the correct LOKRING connector.
The relevant connection point is on the filter dryer to the capillary tube.
The conclusion is valid for both refrigerants, R134a and R600a.
The order number for the LOKRING connector 5/1,8NR MS 00 is: 4801 331 00001