0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range
Single Side Return Air − Air volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) clean-
able air filter in order to maintain proper air velocity across the filter.
Blower Control Factory Settings
ADJUST"
Switch
1
Positions
cfm
+" (Plus)
1415
NORM (Normal)
1285
" (Minus)
N/A
ADJUST"
Switch
1
Positions
cfm
+" (Plus)
1300
NORM (Normal)
1180
" (Minus)
N/A
NOTES − The effect of static pressure and filter resistance is included in air volumes shown.
1st stage HEAT is approximately 91% of the same 2nd stage HEAT speed position.
1st stage COOL (two speed air conditioning units only) is approximately 70% (65% for units built prior to 09−2002) of the same 2nd stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same 2nd stage COOL speed position.
Lennox Harmony IIt zone control applications − Minimum blower heating speed is approximately 75% of the 1st stage HEAT speed position.
Lennox Harmony IIt zone control applications − Minimum blower cooling speed is approximately 45% of the 2nd stage COOL speed position.
N/A − 1st stage HEAT, speed position 1 with
cfm
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
Model
Input
Gas
Required
Size
Conversion
Kit
Nat.
N/A
070−1 to −6
LPG
59M13
Nat.
N/A
090−1 to −6
LPG
59M13
Nat.
N/A
110/135−1 to
−6
LPG
59M13
Nat.
N/A
070−7 and
later
LPG
59M13
Nat.
N/A
090−7 and
later
LPG
59M13
Nat.
N/A
110/135−7
and later
LPG
59M13
Pressure switch is factory set. No adjustment necessary. All models use the factory installed pressure switch from 0−4500 feet (0−1370 m).
ADJUST − NORM
HEAT − 2
COOL − 4
2nd Stage HEAT" Speed
2
3
L/s
cfm
L/s
cfm
665
1625
765
1820
605
1475
695
1655
N/A
1330
625
1490
1st Stage HEAT" Speed
2
3
L/s
cfm
L/s
cfm
615
1480
700
1660
555
1345
635
1510
N/A
1210
570
1360
" (Minus) Adjust" setting, cannot be used with this model.