SECTION 5
5A.
AUTOMATIC ELECTRONIC DIAGNOSTICS
The face plate computer has a self-diagnostic
function for the electrical system (except input
power and water meter). The
computer monitors the elec-
tronic components and circuits
for correct operation. If a
malfunction occurs, an error
code appears in the face plate
display.
MOST LIKELY
CODE
Err1
motor inop. / wiring harness or connection to switch / position switch / face plate
Err2
face plate
Err3
motor / face plate
Err4
face plate / position switch
Err5
face plate
PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplug transformer 2. Correct defect
3. Plug in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.
MANUAL INITIATED ELECTRONICS DIAG-
NOSTICS
1.
To enter diagnostics¼
- ---from a error code display, press the #1
SELECT button.
----from a time display, press and hold the #1
SELECT button for 3 seconds.
You will see 1 of the following displays.
TROUBLESHOOTING
The chart below shows the error codes that could
appear, and the possible defects for each code.
While an error code appears in the display, all face
plate buttons are inoperable except the SELECT
button. SELECT remains operational so the service
person can make the MANUAL INITIATED
ELECTRONIC DIAGNOSTICS (below) to further
isolate the defect, and check the water meter.
POSSIBLE DEFECT
See face plate replacement on
See face plate replacement on
page 22.
page 22.
All of the preceeding displays show what position
the valve is in, if the turbine is operating, and the
position switch open or closed status.
2.
Press the ON/OFF-HOLD button to advance
the valve to the next position. To verify
component operation, or to possibly isolate a
defect, observe the following.
POSITION SWITCH STATUS: WIth the valve in
service, or any of the recharge cycles, the switch
indicator will show open
rotating from 1 position to another, the indicator
will show the switch closed
probable if indications vary from this pattern.
21
SERVICE TECH INFORMATION
LESS LIKELY
. While the valve is
. A defect is

Hide quick links: