SECTION 4
4A.
FIG. 12
BYPASS VALVES
MODEL NO. 625.3485400 AND 625.3485500
NOTE: Please see the rating decal for water softener operating capacity, salt usage and service flow
rate/pressure loss performance specifications. Performance specifications are validated by the Water
Quality Association (WQA). The rating decal is located on the rim, under the salt hole cover (see page
28).
WATER SUPPLY TO WATER SOFTENER
MINIMUM WATER SYSTEM FLOW (gpm)
MINIMUM-MAXIMUM WATER PRESSURE (psi)
MAXIMUM WATER TEMPERATURE (° F)
MAXIMUM WATER HARDNESS (gpg)
MAXMUM " CLEAR WATER"IRON (ppm)
SALT FOR WATER SOFTENER
TYPE OF SALT NEEDED
ALTERNATE TYPE OF SALT
STORAGE CAPACITY (pounds)
DIMENSIONS/SPECIFICATIONS
20-120
120
110
Nugget/Pellet
Pure, evaporated, compacted
water softener salt
200
OTHER THINGS TO KNOW
A
Salt Tank Height
B
Resin Tank Diameter (nominal)
C
Resin Tank Height (nominal)
D
Inlet-Outlet Height
E
Overall Height
1
F
Length
2
F
Width
—
Distance between inlet-outlet
center lines
TIMER AR CODE AR31
OTHERS
3
TYPE OF ION EXCHANGE MATERIAL (resin)
AMOUNT OF RESIN (cu.ft.)
REGENERATION (RECHARGE) CYCLE TIME (min.)
FILL
8
BRINING/BRINE RINSE
BACKWASH
FAST RINSE
TOTAL REGENERATION TIME
gpm = gallons per minute
gpg = grains per gallon
19
INCHES
CM
40-1/4
102.2
9
22.7
40
101.6
41-1/2
105.4
46
116.8
19-1/2
49.5
16-1/2
41.9
3-3/8
8.6
High Capacity
1.0
2.7-10.3
97-106
109.7-126.3
psi = pounds per square inch
ppm = parts per million
7
3