A A
A
Salt Tank Height
B
Resin Tank Diameter
(nominal)
C
Resin Tank Height (nominal)
D
Inlet-Outlet Height
E
Overall Height
F
1
Length
F
2
Width
-
Distance between inlet-outlet
centerlines
WATER SUPPLY TO WATER SOFTENER
Minimum water system flow (gpm)
Minimum-maximum water pressure (psi)
Minimum-maximum water temperature (°F)
Maximum water hardness (gpg)
Maximum "clear water" iron (ppm)*
SALT FOR WATER SOFTENER
Type of salt needed
Alternate type of salt
* Capacity to remove clear water iron is substantiated by WQA test data. State of Wisconsin requires additional treatment if water supply contains
greater than 5 ppm clear water iron.
36
Specifications
F
E
D
B
C
Inches
34
10
40
41-1/2
48
21
17
3-3/4
MODEL 384260 TIMER CODE H46
MODEL 394260 TIMER CODE H47
gpm = gallons per minute
psi = pounds per square inch
Questions? Call The Kenmore Water Line 1-800-426-9345
Bypass valve(s) should always remain in soft water
service position. Position in "bypass" only if needed for
softener repairs.
3 VALVE BYPASS
CM
FOR SERVICE
86.4
close bypass valve
open inlet & outlet valves
25.4
FOR BYPASS
open bypass
101.6
close inlet & outlet
105.4
121.9
53.3
43.2
8.6
MODEL 384260
3
20 - 125
40 - 120
160
11
nugget
pure, evaporated, compacted
water softener salt
gpg = grains per gallon
ppm = parts per million
BYPASS VALVES
SINGLE BYPASS
outward for
Outlet
valve
MODEL 394260
3
20 - 125
40 - 120
160
11
nugget
pure, evaporated, compacted
water softener salt
pull stem
service
push
inward for
bypass
Bypass
valve
Inlet
valve
FIG. 59