Safety
Precautions
_,WARNING
I
The water heater wi_talled
must be prep- I
erly vented
to a chimney
which terminates
outdoors.
I
Never operate the water heater unless it is vented to the
outdoors and has adequate
air supply to avoid risks of
improper operation, explosion or asphyxiation.
AWARNING
Hinimum
clearances between the water heater and com-
bustible construction are 0" at the sides and rear, 5" at the
front, and 0" from the vent pipe. Clearance from the top
of the jacket is 14" on most models. Note that a lesser
dimension may be allowed on some models. Refer to the
label on the water heater adjacent to the gas control valve
for all clearances.
•,WARNING
--1
Do not use this appliance if any part of it has been under I
water.
Immediately
call a Sears Service Technician
to I
inspect the appliance and to replace the gas control or any I
part of the burner system which has been under water.
|
_WARNING
I
Vent termination
must not be within 4 feet of any items
such as gas meters,
gas valves or other gas regulating
equipment.
ACAUTION
WATER
HEATERS
EVENTUALLY
LEAK: Installation
of
the water heater must be accomplished in such a manner
that if the tank or any connections should leak, the flow of
water will not cause damage to the structure. When such
locations cannot be avoided, a suitable drain pan should
be installed under the water heater. Drain pans are avail-
able at your local Sears store. Such a drain pan must be
not greater
than
11/2 inches deep, have a minimum
length and width of at least 2 inches greater
than the
water heater dimensions and must be piped to an ade-
quate drain. The pan must not restrict
combustion
air
flow. Under
no circumstances
is the manufacturer
or
Sears to be held liable for any water damage in connec-
tion with this water heater.
_,WARNING
HYDROGEN
GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of
time
(generally
two
weeks or more).
Hydrogen
gas is
extremely
flammable
and explosive. To prevent the possi-
bility of injury under these conditions, we recommend
the
hot water faucet
be opened for several minutes at the
kitchen sink before any electrical
appliances which are
connected to the hot water system are used (such as a
dishwasher or washing machine).
If hydrogen gas is pre-
sent, there will probably be an unusual sound similar to air
escaping through
the pipe as the hot water
faucet
is
opened. There must be no smoking or open flame near
the faucet at the time it is open.
AWARNING
INSULATING
JACKETS:
When
installing
an external
water heater insulation jacket on a gas water heater:
• DO NOT cover the temperature-pressure
relief valve.
• DO NOT put insulation over any part of the top of the
gas water heater.
• DO NOT put insulation over the gas control valve or gas
control valve/burner
cover, or any access areas to the
burner.
• DO NOT let insulation around the gas water heater to
get within
8 inches of the floor (air must get to the
burner).
• DO NOT cover or remove
operating
instructions, and
safety related warning labels and materials affixed to the
water heater.
Failure to heed this will result in the possibility of a fire or
explosion.