Replacing T He Pilot/Pilot T Ubeassembly; Cleaning The Combustion Chamber Andflame-Arrestor; Replacing T He Manifold/Burner Assembly - Kenmore 153:331472 Owner's Manual

Power miser 12 series 40/50 gallon
Table of Contents

Advertisement

6.
Position the new thermocoupte through the bottom opening
of the two piece wire connector (Figure 34). Be sure igniter
wire is positioned
through the small opening
of the two
piece wire connector.
7.
Re-attach
the burner. Note the orientation
of the burner
(Figure 33.)
8.
See "Replacing the Manifold/Burner
Assembly."
FERROLE
NUT il
IGNITER
WIRE
:' i!
PILOT
PILOT
BRACKET
',,,
_
OTHER
FITTINGS
_i""L
i i
C."-
_
_,.
NOT ....... SHOWN
_
_]
RETAINER
P LC T " UE E
_
MANIFOLD/BU
RNER
(_
t_T_
IWFOEPc_EoCN_
.....
D ..........
FIGURE 34.
FIGURE 35.
Replacing
the Pilot/Pilot
Tube Assembly
1.
Remove the manifold/burner
assembly.
See "Removing
the Manifold/Burner
Assembly."
2.
Lift the retainer clip straight up from the back of the two
piece wire connector (using a flat-blade screwdriver), then
remove the two piece wire connector
from the manifold
door (Figure 34.)
IMPORTANT: Be careful not to bend or alter the position of the
pilot tube.
It will be used as a bending template for the new
pilot assembly.
3.
Take off the burner by removing the two (2) screws located
underneath the burner. See Figure 33.
4.
Remove and keep the screw securing the pilot assembly to
the pilot bracket. (Figure 36)
5.
Remove and keep the old pilot/pilot tube assembly.
6.
Using the old pilot/pilot
tube assembly as a guide, bend
the new pilot tube and new thermocouple
to match the
old ones. NOTE: Make only the bends closest to the pilot
before going to the next step. (Figure 36)
SCREW
PILOTTUBE
OTHER FITTINGS
NOT SHOWN
FOR CLARITY
7.
8.
9.
Route the new pilot tube, thermocoupte,
and igniter wire
through the manifold/burner
door opening. (Figure 34)
Re-attach the pilot assembly to the pilot bracket and secure
using the screw removed earlier.
Position the new pilot tube through the largest opening of
the two piece wire connector.
NOTE: The largest opening
should
be located at the top position.
The igniter wire
should be located in the middle opening and thermocouple
in the bottom opening. (Figure 37)
10.
11.
PILOT
TUBE
IGNITER
WIRE
THERMOCOUPLE
TWO
PIECE
WIRE
CONNECTOR
FIGURE 37,
Reposition
the two piece wire connector
in the manifold
door opening and secure it with the retainer clip.
Carefully
bend the new pilot tube and thermocoupte
to
match the bend of the manifold tube. NOTE: When bending,
DO NOT crimp or crease the pilot tube or thermocouple.
(Figure 34)
12. Before you proceed to the next step, install the new brass
ferrule nut in the gas control valve/thermostat's
pilot tube
opening. HAND TIGHTEN ONLY.
13. See "Replacing
the Manifold/Burner
Assembly."
Cleaning
the Combustion
Chamber
and
Flame-arrestor
1.
2
Follow
procedure
outlined
in "Removing
the Manifold/
Burner Assembly."
Use a vacuum cleaner/shop vac to remove all loose debris
in the combustion
chamber (Figure 38). Use compressed
air to clear any dust or debris that may have accumulated
in the flame-arrestor.
COMBUSTION
CHAMBER
FLAME ARRESTOR
DOOR GASKET
BASE-RING
IGNITER
WIRE
THERMOCOUPLE
FIRST
BEND(S)
FIGURE 36.
3.
FIGURE 38.
Reassemble
by following the procedure under "Replacing
the Manifold/Burner
Assembly."
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.331572

Table of Contents