Troubleshooting
Guide (cont'd)
HIGH
TEMPERATURE
SHUT
OFF SYSTEM
This water heater is equipped with an automatic gas shut offsys-
tern. The high temperature shut off is built into the gas control
waive. This system shuts off the gas supply to the water heater
burners when high water temperatures
are present. It is non-
resettable. If the high temperature shut offactivates, the gas con-
tro[ valve must be replaced. If this were to occur, turn "OFF" the
entire gas supply to the water heater• Contact the Sears Service
Center.
I
AWARNING
Should overheating occur or the gas supplyfail to shut off,
turn "OFF" the manual gascontrol valve to the appliance.
AWARNING
Due to the nature of the typical gas water heater, the
Iwater temperature in certain situations may be hotter
than the thermostat $etUng.
Short, frequent draws of hot water - especiallywith very
cold
incoming water,
can shockthe thermostat into br_f
operation resulting in hotter and hotter layers of water
closerto the top of the tank.
Changes in hot water usage patterns or raisingthe tem-
perature differential between the cut-on of the thermo-
stat and the cold water temperature will usuallyeliminate
the problem.
NOT
ENOUGH
OR NO
HOT
WATER
i
Check the manual gas shut offvalve to be sure it is open.
Check the pilot flame. It may have gone out. All models have
an opening behind the outer door for viewing the pilot.
If the pilot is not lit, follow the Lighting" instructions in this
manual or located above tEe gas control valve on the water
heater to relight the pilot. If the water was extremely hot and is
now cold, the high limit safety temperature shut off may have
put out the burner and pilot. If the high temperature shut off
activates, thegns controlvalve must be replaced. Contact the
Sears Service Center.
_i The gas rX_ntrolknob must be turned to the "ON" position.
The temperature adjustment dial may be set too low. See the
"Tempetatuse Regulation section.
The gas company can check the gas input to see if it is correct.
An underfired water heater will not heat water as quickly.
Look for leaking or open hot water faucets. Make sure all are
dosed.
• The cold water inlet temperature may be colder during the
winter months. It will take longer to heat the water and seem
like less hot water.
• If you cannot find what is wrong, call the Sears Service
Center.
WATER
IS TOO
HOT
• The temperature adjustment dial may be set too high, See the
Temperature
Adjustment
section,
NOTE: A period of time is necessary after an adjustment
has been made for the water temperature
to reach the new
temperxture
setting.
• If lower temperature settlngs will not lower the water tempera-
ture, call the Sears Service Center,