Check monthly
Pilot burner flame
pilot flame (see
Proper
1. Blue flame.
2. Inner cone engulfing pilot flame sensor.
3. Pilot flame sensor glowing cherry red.
Improper
1. Overfired — Large flame lifting or blowing past pilot
flame sensor.
2. Underfired — Small flame. Inner cone not engulfing
pilot flame sensor.
3. Lack of primary air — Yellow flame tip.
4. Incorrectly heated pilot flame sensor.
Main burner flame
main burner flame (see
Proper
1. Yellow-orange streaks may appear (caused by dust).
Improper
1. Overfired — Large flames.
2. Underfired — Small flames.
3. Lack of primary air — Yellow tipping on flames
(sooting will occur).
Service periodically . . . . . . . . . .

Test low water cutoff (if installed)

If the system is equipped with a low water cutoff, test the low water cutoff periodically during the heating season,
following the low water cutoff manufacturer's instructions.