NuTone QuieTTest QT700 Installation Instructions Manual

Twin blower ventilator
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

QuieTT est
Twin Blower Ventilator
MODELS: QT

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE.
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact
the manufacturer.
B. Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent power
from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to
the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must
be marked as appropriate for the application.
F. NEVER place a switch where it can be reached from
a tub or shower.
DESCRIPTION
Designed for ceiling installation.
Refer to Figure 8. Not for use in cooking area.
Uses 6" x 19" duct.
Suitable for use with solid-state speed controls.
Do not cover with insulation of a value greater than R-40.
The ventilator consists of the housing, mounting brackets,
junction box, power unit/blower assembly, damper section
and grille assembly.
®
700 & QT 1000
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
HOUSING DIMENSIONS
15
18
"
16
7
5
"
8
7"
FOR BEST RESULTS
Refer to Figure 1 for dimensions of the housing.
When installing the ventilator in a new construction site,
install housing during the rough-in construction of the
building. The power unit and grille should be installed after
the finished ceiling is in place.
To install the ventilator in an existing building, an
accessible area (attic or crawl space) is required from
above the planned location.
PREPARATION
Unplug the electrical connector from the blower. Do not
pull on plug wires.
Remove the power unit from the housing assembly.
1
(a) Remove 9
" hex nuts holding power unit in place.
16
(b) Pivot the blower assembly slightly toward the back
of the housing and lift straight out.
(c) Set the power unit aside.
7
15
"
16
1
23
"
4
11
21
"
16
FIGURE 1
7
14
"
8

Advertisement

Table of Contents
loading

Summary of Contents for NuTone QuieTTest QT700

  • Page 1: Important Safety Instructions

    INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS! QuieTT est ® Twin Blower Ventilator 700 & QT 1000 MODELS: QT IMPORTANT SAFETY INSTRUCTIONS HOUSING DIMENSIONS WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 2: Ducting Options

    DUCTING OPTIONS Refer to Figures 2 and 3. The ventilators may be ducted either horizontally or vertically. As illustrated, position and secure the damper section to the housing in the desired position. VERTICAL DISCHARGE HORIZONTAL DISCHARGE SCREWS (8) SCREWS (8) FIGURE 2 FIGURE 3 VENTILATOR...
  • Page 3 OPTIONAL MOUNTING METHODS The mounting brackets may be adjusted and/or moved for various types of installation. To adjust bracket position, loosen ⁄ " hex nuts and Reverse brackets to allow approximately 1" of additional move brackets up or down. Re-tighten hex nuts securely. clearance space.
  • Page 4: Power Unit Installation

    4. Replace junction box and tighten screws. 5. Connect supply wire to switch. NOTE: Switch must be purchased separately. Refer EARTH to NuTone's catalog for complete ordering information. GROUND 120vAC, 60 Hz POWER UNIT INSTALLATION HOUSE POWER FIGURE 7 1.
  • Page 5: Directives D'installation

    INSTRUCTIONS D'INSTALLATION LIRE ET CONSERVER CES INSTRUCTIONS Ventilateur QuieTT est ® DIMENSIONS DU BOITIER à rotor double ⁄ ⁄ 700 & QT 1000 MODELES: QT DESCRIPTION ⁄ • Concu pour installation au plafond. ⁄ • ATTENTION: Pour réduire le risque de décharge électrique, couper le courant avant tout entretien.
  • Page 6 OPTIONS D'EVACUATION Voir Figures 2 et 3. Les ventilateurs sont prévus pour évacuation horizontale ou verticale. Placer et fixer le registre au boîtier en position voulue, comme illustré. EVACUATION VERTICALE EVACUATION HORIZONTALE VIS (8) VIS (8) FIGURE 2 FIGURE 3 VENTILATEUR FIGURE 4 MONTAGE DU BOITIER...
  • Page 7 AUTRE METHODES DE MONTAGE On peut ajuster ou enlever les pattes de fixation pour divers types d'installation. Pour adjuster la position des pattes, desserrer les Retourner les pattes pour permettre environ 1 po écrous hexagonaux de ⁄ po et déplacer les pattes vers d'espace supplémentaire.
  • Page 8: Installation De La Grille

    Raccorder le fil de terre à la vis de terre verte. 4. Replacer le boîtier de raccordement et serrer les vis. 5. Reccorder le câble d'alimentation à l'interrupteur. REMARQUE: L'interrupteur peut être acheté séparément. Voir le catalogue NuTone pour les rensignements comlpets TERRE de commande. COURANT DOMESTIQUE...
  • Page 9: One Year Limited Warranty

    WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING.