Page of 8
Download Bookmark Comment

NuTone QTXN110HL Instructions Manual

Hide thumbs
   
MODEL QTXN110HL
Page 1
QTXN SERIES
HEATER / FAN / LIGHT /
NIGHT LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
ance - lower or remove grille and vacuum interior of unit with the
JURY TO PERSONS, OBSERVE THE FOLLOWING:
dusting brush attachment.
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
The motor is permanently lubricated and never needs oiling. If
or telephone number listed in the warranty.
the motor bearings are making excessive or unusual noises,
replace the motor with the exact service motor. The impeller should
2. Before servicing or cleaning unit, switch power off at service
also be replaced.
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
Replace light bulbs with (2) 60-Watt (maximum) incandescent
vice disconnecting means cannot be locked, securely fasten
light bulbs and (1) 7-Watt night light bulb.
a prominent warning device, such as a tag, to the service
panel.
OPERATION
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
Use a 4-Function Control to operate the heater, fan, light, and
and standards, including fire-rated construction codes and
night light separately. See "Connect Wiring" for details.
standards.
4. Sufficient air is needed for proper combustion and exhaust-
NOTE: This unit is designed with a thermostat which senses
ing of gases through the flue (chimney) of fuel burning equip-
excess heat and may start the blower automatically. This is normal
ment to prevent backdrafting. Follow the heating equipment
and is no cause for concern.
manufacturer's guideline and safety standards such as those
NOTE: Fan may cycle when light is on. Blinking light may indi-
published by the National Fire Protection Association (NFPA),
cate improper lamp wattage or type.
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
WARRANTY
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
NUTONE THREE YEAR LIMITED WARRANTY
6. Ducted fans must always be vented to the outdoors.
NuTone warrants to the original consumer purchaser of its products that such products will
be free from defects in materials or workmanship for a period of three years from the date of
7. Provide a separate 20 AMP circuit. Use 12 GA. power cable
original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, IN-
of type which meets code.
CLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
8. This unit must be grounded.
During this three-year period, NuTone will, at its option, repair or replace, without charge,
any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND
TUBES. This warranty does not cover (a) normal maintenance and service or (b) any prod-
!
ucts or parts which have been subject to misuse, negligence, accident, improper mainte-
CAUTION
nance or repair (other than by NuTone), faulty installation or installation contrary to recom-
mended installation instructions.
The duration of an implied warranty is limited to the three-year period as specified for the
1. For general ventilating use only. Do not use to exhaust haz-
express warranty. Some states do not allow limitation on how long an implied warranty
ardous or explosive materials and vapors.
lasts, so the above limitation may not apply to you.
NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE'S OPTION, SHALL BE
2. This product is designed for installation in ceilings up to a
THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY.
12/12 pitch. Duct connector must point up. DO NOT MOUNT
NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
THIS PRODUCT IN A WALL.
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFOR-
MANCE. Some states do not allow the exclusion or limitation of incidental or consequential
3. To avoid motor bearing damage and noisy and/or unbalanced
damages, so the above limitation may not apply to you.
impellers, keep drywall spray, construction dust, etc. off power
This warranty gives you specific legal rights, and you may also have other rights, which vary
unit.
from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify NuTone at the address or telephone
4. Please read specification label on product for further informa-
number stated below, (b) give the model number and part identification and (c) describe the
tion and requirements.
nature of any defect in the product or part. At the time of requesting warranty service, you
must present evidence of the original purchase date.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
Installer: Leave this manual with the homeowner.

   Related Manuals for NuTone QTXN110HL

   Summary of Contents for NuTone QTXN110HL

  • Page 1

    This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify NuTone at the address or telephone 4. Please read specification label on product for further informa- number stated below, (b) give the model number and part identification and (c) describe the tion and requirements.

  • Page 2: Typical Installation

    MODEL QTXN110HL Page 2 TYPICAL INSTALLATION INSTALLATION 1. Insert CEILING POWER mounting MOUNTING JOIST, TRUSS, CABLES CHANNELS brackets. OR I-JOISTS Slide the (4) mounting brackets into the HOUSING channels on each end of the housing. CEILING GRILLE MATERIAL 2. Mount housing.

  • Page 3

    FAN (2-position rocker) RATING SPECIFICATIONS 9. Attach HEAT (2-position rocker) • The three-position rocker switch is rated 5 A grille. NuTone 4-Function @ 125VAC. Use this switch 4-FUNCTION CONTROL Remove the (2) Control shown for Lights ONLY. 120 VAC LINE IN...

  • Page 4: Service Parts

    MODEL QTXN110HL Page 4 SERVICE PARTS Key No. Part No. Description 97016470 Housing 98007763 Slide Channel (2 req.) 98003036 Support Angle (4 req.) 97016450 Duct Connector 99170245 Screw #8-18 X .375 (8 req.) 93260454 Nut, Sheet Metal #8-18 (Partition) (2 req.) 99260512 Nut, Sheet Metal #8-18 (Grille) (3 req.)

  • Page 5: Limpieza Y Mantenimiento

    Para calificar en la garantía de servicio, usted debe (a) notificar a NuTone al domicilio o al número 4. Lea la etiqueta de especificaciones del producto para ver de teléfono abajo, (b) dar el número del modelo y la identificación de la pieza, y (c) describir la naturaleza de cualquier defecto en el producto o pieza.

  • Page 6

    MODELO QTXN110HL Página 6 INSTALACIÓN TÍPICA INSTALACIÓN 1. Inserte los soportes de CABLES DE VIGA DE TECHO, ELECTRICIDAD TIRANTE O montaje. RANURAS VIGA EN I DE MONTAJE Deslice los (4) soportes de montaje en las CUBIERTA ranuras en cada extremo de la cubierta.

  • Page 7

    DEL GRADO CALENTADOR ROJO (interruptor 2-posición) • El interruptor de eje 9. Fije la rejilla. de balancín de tres NuTone control para CONTROL DE 4 FUNCIONNES 4-funciones ilustrado Quite los dos (2) posiciones es clasificado LINEA DE ENTRADA (comprar separado) tornillos de 5 A @ 125VCA.

  • Page 8

    MODELO QTXN110HL Página 8 PIEZAS DE REPUESTO Clave No. Pieza No. Descripción 97016470 Cubierta 98007763 Ranura de deslizamiento (se req. 2) 98003036 Ángulo de soporte (se req. 4) 97016450 Conector del conducto 99170245 Tornillo, #8-18 x 0.375 (se req. 8) 93260454 Tuerca de chapa #8-18 (División) (se req.

Comments to this Manuals