Panasonic KX-TG3411BXH Service Manual page 33

2.4 ghz digital cordless phone solution
Table of Contents

Advertisement

10.1.3.2. Handset
Does Handset make link with Base Unit?
(Correct working unit)
NO
Is the voltage of TP VBAT about 2.2~2.8 V?
YES
Is the voltage of TP VDDC about 1.8 V?
YES
Is the voltage of TP 3.0 V about 3.0 V?
YES
Does the RF clock (CLK) oscillate: 13.824 MHz
in Handset Test Mode?
YES
Check the RF part
Cross Reference:
Power Supply Circuit/Reset Circuit (P.20)
Check the RF part (P.34)
Note:
*1 How to adjust +3.0V:
Execute the command "VDA"
Refer to Things to Do after Replacing IC or X'tal (P.54) for Handset.
*2 How to adjust the frequency of X1:
To see the frequency, execute the command "SFR", then check the TP_CKM (IC1-57pin).
To adjust frequency, send command "SFR
YES
Handset is OK. Check Base Unit.
NO
Check the batteries.
NO
Check around Power Supply Circuit/Reset Circuit.
OR
Adjust +3.0V Vottage to 3.0V
NO
Check around X1 and RF module and adjust
clock frequency.
"until the frequency counter becomes13.824 MHz±55HZ.
33
KX-TG3411BX/KX-TG3412BX/KX-TG3419BX/KX-TGA341BX
*1
*2

Hide quick links:

Advertisement

Table of Contents
loading