Compressor - LG GB7143**AV Series Service Manual

Table of Contents

Advertisement

6) LED blinks seven times, then repeats (IPM Fault)
Purpose: Prevent high current due to IPM Short
Cause: Damaged IPM (Dead Short)
Test for a dead short at Point A with a VOM.
Logic: Compressor is forced off and tries to restart in 2.5 minutes.
A
Protection
Blink 7 times
logic
(Lock Piston Trip)
Check B
Check B5
Check IPM
Short
N
Y

Compressor

Replace
visual inspection
Test
Doesn't work
Drive PCB
(turn off)
Point A
N
Y
Repeat
Check Procedure
Compressor
Y
Power
Damage
Reset
Check C3
NG
Replace
Compressor
- 22 -