Installing
LP Gas Fuel Gauge Assembly
1.
Unscrew the M18x1.5 and M8x1.25 nuts from
the Pressure Cylinder.
2.
Unscrew and remove the Fixing Ring from the
Dial. See Fig. 10a.
3.
Insert the end with Pressure Cylinder through
the notched hole on right Side Shelf. See
Fig. 10b. Turn the Dial until it matches the
notched hole, and push it into the hole.
4.
Screw the Fixing Ring back to the Dial from
the Pressure
Cylinder side. See Fig. 10c.
5.
Insert the Pressure Cylinder into Pressure
Cylinder Guide, and secure using the de-
tached M18x1.5
nut. See Fig. 11.
6.
Attach Tank Hook to the lower thread of
Pressure Cylinder, and secure firmly using the
detached
M8x1.25
nut. Once tank is
connected,
the dial wilt indicate amount of
gas in tank.
Your natural gas grill is designed to operate on
natural gas only, at a pressure of 7" water column
(W.C.) (1/4 psig or 1.75 kpa), regulated at the
residential meter. Check with your gas utility
company for local gas pressure and with your local
municipality for building code requirements. If your
residential gas line pressure has not been regu-
lated to 7" W.C., contact your local gas utility
company for professional assistance.
It is recommended that a ShutoffValve be installed at
the gas supply source outdoors. Install at a point after
the gas pipe exits the outside walt and before the
quick-disconnect hose, or install it at the point before
the gas line piping enters the ground.
Pipe sealing compound or pipe thread tape
resistant to the action of natural gas must be used
on all male pipe threads when making the
connection.
Disconnect your gas grill from fuel source when
the gas supply is being tested at high pressures.
This gas grill and its individual shutoff valve must
be disconnected from the gas supply pipe system
during any pressure testing of that system at
pressure in excess of 1/2 psi (3.5kpa).
Turn off your gas grill when the gas supply is
being tested at low pressures. The grill must be
isolated from the gas supply pipe system by
closing its individual manual shutoff valve during
any pressure testing of the gas supply pipe
system at pressures equal to or less than 1/2 psi
(3.5kpa).
Figure lOa
PRESSURE
CYLINDER
Figure lOb
DIAL
Figure 10c
Figure 11
DIAL
FIXING RING
NOTCHED
HOLE
PRESSURE
CYLINDER
FIXING RING
PRESSURE
CYLINDER
TANK GUIDE
_PRESSURE
CYLINDER
PRESSURE
CYLINDER
GUIDE
14

Advertisement

loading

This manual is also suitable for:

141.1786141.178600141.168600