Insta{ling LP Gas Fuem GaugeAssemb{y
1. Unscrew the M18x1.5 and M8x1.25 nutsfrom
the Pressure Cylinder.
2. Unscrew and removethe FixingRingfromthe
Dial.See Fig. 10a.
3. insertthe end with Pressure Cylinder t hrough
the notchedhole on right SideShelf.See
Fig. 10b. Turn the Dial until it matchesthe
notchedhole,and pushit into the hole.
4. Screwthe FixingRing backto the Dial from
the Pressure Cylinder s ide. See Fig. 10c.
5. insertthe Pressure Cylinderinto Pressure
CylinderGuide,and secureusingthe de-
tachedM18x1.5 nut. See Fig. 11.
6. AttachTank Hookto the lowerthreadof
Pressure Cylinder, a nd securefirmly usingthe
detachedM8x1.25 nut. Oncetank is con-
nected,the dial will indicateamountof gas
in tank.
Figure10a
FigurelOb
DIAL
FIXING
RING
NOTCHED
HOLE
PRESSURE
CYLINDER
Your natural gas grill is designed to operate on
natural gas only, at a pressure of 7" water column
(W.C.) (1/4 psig or 1.75 kpa), regulated at the
residential meter. Check with your gas utility
company for local gas pressure and with your local
municipality for building code requirements. If your
residential gas line pressure has not been regu-
lated to 7" W.C, contact your local gas utility
company for professional assistance.
It is recommended that a ShutoffValve be installed at
the gas supplysource outdoors. Install ata point after
the gas pipe exits the outside wall and before the
quick-discon nect hose, or install it at the point before
the gas line piping enters the ground.
Pipe sealing compound or pipe thread tape
resistant to the action of natural gas must be used
on all male pipe threads when making the
connection.
Disconnect your gas grill from fuel source when
the gas supply is being tested at high pressures.
This gas grill and its individual shutoffvalve must
be disconnected from the gas supply pipe system
during any pressure testing of that system at
pressure in excess of 1/2 psi (3.5kpa).
Turn off your gas grill when the gas supply is
being tested at low pressures. The grill must be
isolated from the gas supply pipe system by
closing its individual manual shutoffvalve during
any pressure testing of the gas supply pipe
system at pressures equal to or less than 1/2 psi
(3.5kpa).
Figure
10c
Figure
11
DIAL
PRESSURE
CYLINDER
TANK
GUIDE
FIXING
RING
CYLINDER
PRESSURE
CYLINDER
GUIDE
_TANKHOOK
13