Water-cooled indoor air conditioner

Advertisement

Quick Links

Water-Cooled Indoor aIr CondItIoner
33WC Model
INSTRUCTION MANUAL
Rev. L
© 2013 Pentair Equipment Protection
P/N 10-1008-63
87976540

Advertisement

Table of Contents
loading

Summary of Contents for Pentair 33WC

  • Page 1 Water-Cooled Indoor aIr CondItIoner 33WC Model INSTRUCTION MANUAL © 2013 Pentair Equipment Protection 87976540 Rev. L P/N 10-1008-63...
  • Page 2: Table Of Contents

    HOLD HARMLESS ..................................11 NOTE: Some of the information in this manual may not apply if a special unit was ordered. If additional drawings for a special unit are necessary, they have been inserted. Contact Pentair Equipment Protection if further information is required.
  • Page 3: Handling & Testing The Air Conditioner

    Damage evident upon receipt should be noted on the freight bill. Damage should be brought to the attention of the delivering carrier -- NOT to Pentair Equipment Protection -- within 15 days of delivery. Save the carton and packing material and request an inspection. Then file a claim with the delivering carrier.
  • Page 4: Installation Instructions

    2500/2500 330416GWXXX 50/60 6.0/5.8 3800/4000 330426GWXXX 50/60 3.3/3.2 3800/4000 XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers DIMENSIONAL DRAWING 89045090 © 2013 Pentair Equipment Protection 87976540 - 4 -...
  • Page 5: Principles Of Operation

    The moisture that the enclosure air can contain is limited. If moisture flows from the drain tube continuously this can only mean that ambient air is entering the enclosure. Be aware that frequent opening of the enclosure’s door admits humid air which the air conditioner must then dehumidify. © 2013 Pentair Equipment Protection 87976540 - 5 -...
  • Page 6: Temperature Control

    If water flow persists, it may indicate a malfunction of the control valve. Information on the specific valve employed is supplied with the air conditioner. © 2013 Pentair Equipment Protection 87976540 - 6 -...
  • Page 7: Maintenance

    An alternate means would be to start the air conditioner and allow the refrigeration system pressure to open the valve while air pressure is applied to inlet. © 2013 Pentair Equipment Protection 87976540 - 7 -...
  • Page 8: Components List

    10-1026-74 10-1016-22 10-1026-74 Thermal Overload 10-1007-19 10-1007-57 10-1007-44 10-1007-57 Compressor Relay 10-1028-20 10-1028-07 10-1028-05 10-1028-07 Start Capacitor None 10-1032-09 None 10-1032-09 For additional technical support, contact Pentair Equipment Protection at 800-896-2665. © 2013 Pentair Equipment Protection 87976540 - 8 -...
  • Page 9 NOTES © 2013 Pentair Equipment Protection 87976540 - 9 -...
  • Page 10: Warranty

    Should any part prove defective within the above warranty period, the customer may choose to return the defective product that is under warranty to Pentair Equipment Protection for repair at no charge or the customer has the option to repair the defective products at his own expense and Pentair Equipment Protection will supply repair parts at no charge providing the defective part is returned and found to have failed under warranty.
  • Page 11: Hold Harmless

    Equipment Protection’s own specifications, provided that the customer or user shall promptly notify Pentair Equipment Protection in writing of any such claim or demand, provided further that Pentair Equipment Protection shall have the right and option to undertake and control the entire defense of such...
  • Page 12 Pentair Equipment Protection 2100 Ho man Way Minneapolis, MN 55303 USA +1.763.422.2211 +1.763.576.3200 PentairEquipmentProtection.com © 2013 Pentair Equipment Protection 87976540 Rev. L P/N 10-1008-63...

Table of Contents