Pentair Genesis Series Instruction Manual

Pentair Genesis Series Instruction Manual

Genesis series
Table of Contents

Advertisement

GENESIS™

Air Conditioner

All Models
INSTRUCTION MANUAL
© 2013 Pentair Equipment Protection
89104462
Rev. B
P/N 89104462

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Genesis Series

  • Page 1: Air Conditioner

    GENESIS™ Air Conditioner All Models INSTRUCTION MANUAL © 2013 Pentair Equipment Protection 89104462 Rev. B P/N 89104462...
  • Page 2: Table Of Contents

    LIMITATION OF LIABILITY ......................................39 NOTE: Some of the information in this manual may not apply if a special unit was ordered. If additional drawings for a special unit are necessary, they have been inserted. Contact Pentair Equipment Protection if further information is required.
  • Page 3: Receiving The Air Conditioner

    Damage evident upon receipt should be noted on the freight bill. Damage should be brought to the attention of the delivering carrier -- NOT to Pentair Equipment Protection -- within 15 days of delivery. Save the carton and packing material and request an inspection. Then file a claim with the delivering carrier.
  • Page 4: Installation Instructions

    5. Refer to top of nameplate for electrical requirements. Connect the power cord to a properly grounded power supply. Use of an extension cord is not recommended. Electrical circuit should be fused with slow blow or HACR circuit breaker. © 2013 Pentair Equipment Protection 89104462 - 4 -...
  • Page 5: M13 Design Data

    M13 DIMENSIONAL DRAWING M13 MOUNTING GASKET AND CUTOUT DIMENSIONS Mounting gasket kit 17-1000-50 included. Apply Dashed lines represent aire conditioner. gasket to the back of the air conditioner before mounting to enclosure. © 2013 Pentair Equipment Protection 89104462 - 5 -...
  • Page 6: M13 Components List

    10-1130-13 10-1130-13 Relay, Compressor, Start 10-1028-05 10-1028-07 Service Cord 52-6035-138 52-6035-139 Terminal Block 10-1003-03 10-1003-03 Thermal Overload, Compressor 10-1007-19 10-1007-58 Thermostat, SPST, 55-100F 10-1061-16 10-1061-16 Transformer, 10 VAC Secondary 10-1006-114 10-1006-115 © 2013 Pentair Equipment Protection 89104462 - 6 -...
  • Page 7: M13 Schematic And Wire Diagram, 115/230 Volt 1000 Btu

    M13 SCHEMATIC AND WIRE DIAGRAM, 115/230 VOLT 1000 BTU © 2013 Pentair Equipment Protection 89104462 - 7 -...
  • Page 8: M17 Design Data

    M17 DIMENSIONAL DRAWING M17 MOUNTING GASKET AND CUTOUT DIMENSIONS Mounting gasket kit 17-1000-50 included. Apply Dashed lines represent aire conditioner. gasket to the back of the air conditioner before mounting to enclosure. © 2013 Pentair Equipment Protection 89104462 - 8 -...
  • Page 9: M17 Components List

    10-1130-18 10-1130-18 Relay, Compressor, Start 10-1028-05 10-1028-07 Service Cord 52-6035-138 52-6035-139 Terminal Block 10-1003-03 10-1003-03 Thermal Overload, Compressor 10-1007-44 10-1007-57 Thermostat, SPST, 55-100F 10-1061-16 10-1061-16 Transformer, 10 VAC Secondary 10-1006-114 10-1006-115 © 2013 Pentair Equipment Protection 89104462 - 9 -...
  • Page 10: M17 Schematic And Wire Diagram, 115 Volt 1800 Btu

    M17 SCHEMATIC AND WIRE DIAGRAM, 115 VOLT 1800 BTU M17 SCHEMATIC AND WIRE DIAGRAM, 230 VOLT 1800 BTU © 2013 Pentair Equipment Protection 89104462 - 10 -...
  • Page 11: M28 Design Data

    16.4/17.2 5400/6000 125/52 120/55 M28-0626-GXXX 50/60 5400/6000 125/52 120/55 -XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers. M28 DIMENSIONAL DRAWING © 2013 Pentair Equipment Protection 89104462 - 11 -...
  • Page 12: M28 Mounting Gasket And Cutout Dimensions

    2. Cutout dimensions are for standard unit. 3. Hole may be deleted if service cord is routed through 3.00 mounting to enclosure. x 13.50 cutout (except on units with electric heat). © 2013 Pentair Equipment Protection 89104462 - 12 -...
  • Page 13: M28 Components List

    Service Cord 52-6035-139 52-6035-139 52-6035-139 Terminal Block (If Installed) 10-1003-31 10-1003-31 10-1003-31 Thermal Overload, Compressor 10-1007-57 10-1007-51 10-1007-49 Thermostat, SPST, 55-100F 10-1061-16 10-1061-16 10-1061-16 Transformer, 10 VAC Secondary 10-1006-115 10-1006-115 10-1006-115 © 2013 Pentair Equipment Protection 89104462 - 13 -...
  • Page 14: M28 Schematic And Wire Diagram, 115 Volt, 2200 Btu And 230 Volt 6000 Btu

    M28 SCHEMATIC AND WIRE DIAGRAM, 115 VOLT, 2200 BTU AND 230 VOLT 6000 BTU M28 SCHEMATIC AND WIRE DIAGRAM, 230 VOLT, 2200 BTU © 2013 Pentair Equipment Protection 89104462 - 14 -...
  • Page 15: M28 Schematic And Wire Diagram, 115/230 Volt, 4000 Btu & 230 Volt 6000 Btu

    M28 SCHEMATIC AND WIRE DIAGRAM, 115/230 VOLT, 4000 BTU & 230 VOLT 6000 BTU M28 SCHEMATIC AND WIRE DIAGRAM, 115 VOLT, 6000 BTU © 2013 Pentair Equipment Protection 89104462 - 15 -...
  • Page 16: M33 Design Data

    3700/4000 131/55 105/48 M33-0426-GXXX 50/60 4.4/4.7 3700/4000 131/55 105/48 -XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers. M33 DIMENSIONAL DRAWING © 2013 Pentair Equipment Protection 89104462 - 16 -...
  • Page 17: M33 Mounting Gasket And Cutout Dimensions

    2. Cutout dimensions for standard unit. 3. Service cord to be routed through 2.00 x 11.12 cutout. mounting to enclosure. 4. Bottom cutout will accomodate air conditioner or heat exchanger. © 2013 Pentair Equipment Protection 89104462 - 17 -...
  • Page 18: M33 Components List

    10-1130-16 Relay, Compressor, Start 89100495 Service Cord 52-6035-143 52-6035-141 Terminal Block (if installed) 10-1003-03 10-1003-03 Thermal Overload, Compressor 10-1007-45 10-1007-51 Thermostat, SPST, 55-100F 10-1061-16 10-1061-16 Transformer, 10 VAC Secondary 10-1006-114 10-1006-115 © 2013 Pentair Equipment Protection 89104462 - 18 -...
  • Page 19: M33 Wire Diagram And Schematic, 115 V, 4000 Btu

    M33 WIRE DIAGRAM AND SCHEMATIC, 115 V, 4000 BTU 89100994 WIRE DIAGRAM, 230 V, 4000 BTU © 2013 Pentair Equipment Protection 89104462 - 19 -...
  • Page 20: M36 Design Data

    50/60 5.0/5.0 5000/6000 105/48 M36-0626-GXXX 50/60 5.0/5.0 5000/6000 105/48 -XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers. M36 DIMENSIONAL DRAWING © 2013 Pentair Equipment Protection 89104462 - 20 -...
  • Page 21: M36 Mounting Gasket And Cutout Dimensions

    1. Dashed lines represent aire conditioner. gasket to the back of the air conditioner before 2. Cutout dimensions for standard unit. 3. Service cord to be routed through 3.00 x 14.00 cutout. mounting to enclosure. © 2013 Pentair Equipment Protection 89104462 - 21 -...
  • Page 22: M36 Components List

    Contactor (optional) 10-1005-41 Service Cord 52-6035-143 52-6035-141 Thermal Overload, Compressor 10-1007-18 MRA5742-114 Thermostat, SPST, 55-100F 10-1061-16 10-1061-16 Transformer, 10 VAC Secondary 10-1006-114 10-1006-115 M36 SCHEMATIC AND WIRE DIAGRAM, 115/230 VOLT 6000 BTU © 2013 Pentair Equipment Protection 89104462 - 22 -...
  • Page 23: M52 Design Data

    -XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers. * Based on return air temperature slightly above ambient. M52 DIMENSIONAL DRAWING © 2013 Pentair Equipment Protection 89104462 - 23 -...
  • Page 24: M52 Mounting Gasket And Cutout Dimensions

    2. Cutout dimensions for standard unit. 3. Hole may be deleted if service cord is routed through 4.50 mounting to enclosure. x 15.63 cutout (except on units with electric heat). © 2013 Pentair Equipment Protection 89104462 - 24 -...
  • Page 25: M52 Components List

    52-6035-139 52-6035-139 52-6035-141 Terminal Block 10-1003-31 10-1003-31 10-1003-31 10-1003-31 Thermal Overload, Compressor 10-1007-11 10-1007-12 10-1007-13 10-1007-13 Thermostat, SPST, 55-100F 10-1061-16 10-1061-16 10-1061-16 10-1061-16 Transformer, 10 VAC Secondary 10-1006-115 10-1006-115 10-1006-115 10-1006-115 © 2013 Pentair Equipment Protection 89104462 - 25 -...
  • Page 26: M52 Schematic And Wire Diagram, 115 Volt 10000 And 12000 Btu

    M52 SCHEMATIC AND WIRE DIAGRAM, 115 VOLT 10000 AND 12000 BTU M52 SCHEMATIC AND WIRE DIAGRAM, 115/230 VOLT 6000/8000 BTU AND 230 VOLT 10000/12000 BTU © 2013 Pentair Equipment Protection 89104462 - 26 -...
  • Page 27: Mhb11 Design Data

    125/52 108/49 MHB11-0426-G3XX 220/230 50/60 8.0/7.5 3300/4000 125/52 108/49 -XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers. MHB11 DIMENSIONAL DRAWING © 2013 Pentair Equipment Protection 89104462 - 27 -...
  • Page 28: Mhb11 Mounting Gasket And Cutout Dimensions

    52-6035-143 52-6035-141 52-6035-141 Terminal Block 10-1003-31 10-1003-31 10-1003-31 10-1003-31 Thermal Overload, Compressor 10-1007-44 10-1007-45 10-1007-57 10-1007-51 Thermostat, SPST, 55-100F 10-1061-16 10-1061-16 10-1061-16 10-1061-16 Transformer, 10 VAC Secondary 10-1006-114 10-1006-114 10-1006-115 10-1006-115 © 2013 Pentair Equipment Protection 89104462 - 28 -...
  • Page 29: Mhb11 Schematic And Wire Diagram, 115 Volt, 2200 Btu And 230 Volt 6000 Btu

    MHB11 SCHEMATIC AND WIRE DIAGRAM, 115 VOLT, 2200 BTU AND 230 VOLT 6000 BTU © 2013 Pentair Equipment Protection 89104462 - 29 -...
  • Page 30: Mhb11 Schematic And Wire Diagram, 230 Volt, 2200 Btu

    MHB11 SCHEMATIC AND WIRE DIAGRAM, 230 VOLT, 2200 BTU MHB11 SCHEMATIC AND WIRE DIAGRAM, 115/230 VOLT, 4000 BTU & 230 VOLT 6000 BTU © 2013 Pentair Equipment Protection 89104462 - 30 -...
  • Page 31 NOTES © 2013 Pentair Equipment Protection 89104462 - 31 -...
  • Page 32: Temperature Control

    Continued operation under the above conditions can and will damage and shorten compressor life. The air conditioner is available with an easily removable inlet filter to facilitate necessary cleaning. There should be no reason to neglect this necessary maintenance. © 2013 Pentair Equipment Protection 89104462 - 32 -...
  • Page 33: How To Remove, Clean Or Install A New Inlet Air Filter

    CAUTION Operation of the air conditioner in areas containing airborne caustics or chemicals can rapidly deteriorate filters, condenser coils, blowers and motors, etc. Contact Pentair Equipment Protection for special recommendations. REFRIGERANT LOSS Each air conditioner is thoroughly tested prior to leaving the factory to insure against refrigeration leaks. Shipping damage or microscopic leaks not found with sensitive electronic refrigerant leak detection equipment during manufacture may require repair or recharging of the system.
  • Page 34: Trouble Shooting

    (replace control box cover for safety). This will activate the switch in the thermostat. Turn the power on and if both blowers and the compressor come on, the thermostat needs to be replaced. © 2013 Pentair Equipment Protection 89104462 - 34 -...
  • Page 35: Symptoms And Possible Causes

    Drain plugged Getting water in enclosure Drain tube kinked Enclosure not sealed (allowing humidity in) For additional technical information (i.e., amp draw, pressures, temperatures) , contact Pentair Equipment Protection at 800-896-2665. © 2013 Pentair Equipment Protection 89104462 - 35 -...
  • Page 36 NOTES © 2013 Pentair Equipment Protection 89104462 - 36 -...
  • Page 37 NOTES © 2013 Pentair Equipment Protection 89104462 - 37 -...
  • Page 38: Warranty

    Pentair Equipment Protection approval. Pentair Equipment Protection must be notified of a claim in writing not later than fourteen (14) days from the date when Buyer has become aware of such occurrence, or where the defect is such that it may cause damage, immediately, such notice containing a description of how the defect manifests itself.
  • Page 39: Limitation Of Liability

    B. All returns to Pentair Equipment Protection must be securely packed, using original cartons if possible. All returns must have the RMA number visible on the outside of the carton. Pentair Equipment Protection is not responsible for material damaged in transit. Any refrigerant-bearing Goods must be shipped upright for return.
  • Page 40 Pentair Equipment Protection 2100 Ho man Way Minneapolis, MN 55303 USA +1.763.422.2211 +1.763.576.3200 PentairEquipmentProtection.com © 2013 Pentair Equipment Protection 89104462 Rev. B P/N 89104462...