Mx7 Desktop Cradle Help - Honeywell MX7 Reference Manual

Hide thumbs Also See for MX7:
Table of Contents

Advertisement

MX7 Desktop Cradle Help

The following is intended as an aid in determining whether the MX7 battery pack or the cradle battery charger may be
malfunctioning.
Problem
Battery pack does not fit
in battery well.
No battery pack in spare
battery charging well,
but the charging LED is
on.
Cradle is plugged into a
live outlet, battery pack
is inserted, but RED
LED is OFF and no
other LEDs are on, or all
LEDs are off.
When you first put a
fully charged battery
pack in the battery well,
the RED LED comes
on, indicating the
battery pack is
charging.
LED is flashing RED at
any station. LED is
flashing RED at any
station.
Solid YELLOW LED
when battery pack is
inserted in the cradle.
Cause
Different manufacturer's battery pack,
or there is an object in the battery well.
Dirt or foreign objects are in the battery
well.
Battery pack is not making contact with
charging terminals in the battery well.
Faulty battery pack.
New battery pack, same result.
During the first few minutes, the
charger checks the battery pack for
correct voltage and charge state.
During this time the LED is RED and is
continuously ON. After charging is
complete, the LED is GREEN.
Current could not be sourced through
the battery pack due to age, exhaustion
or damage to the cell(s).
 Or
The battery pack does not
communicate with the charger.
The charger's timeout period has
expired.
The battery pack is too hot or too cold
to charge.
Solution
Check if the battery pack is Honeywell part number
MX7A380BATT / MX7392BATT or a Low Temperature
(CS) Battery : MX7A381BATT / MX7393BATT /
MX7396BATTERY . If not, do not use.
Remove the object from the battery well.
Unplug cradle from outlet. Remove any dirt or foreign
objects from battery well.
If the LED continues to stay ON, the cradle may be
defective. Return charger to an authorized Honeywell
service center.
Push battery pack in firmly. Do not "slam" the battery
pack into the battery well.
Replace battery pack.
Contact Honeywell for replacement options.
There is nothing wrong with the battery pack or charging
pocket.
Contact Honeywell for battery pack replacement options.
Make sure that the battery pack temperature is within
specification and retry charging. If problem repeats,
contact Honeywell for battery pack replacement options.
Remove battery pack from the cradle and allow it to
adjust to room temperature.
If the battery pack is left in the cradle, it will cool down or
warm to a temperature upon which the cradle will begin
the charge cycle. However, depending on the
2-15