Electricity Supply; Technical Data - Potterton Prorile Prima 30e Installation And Servicing Instructions

Fanned balanced flue gas fired boilers
Hide thumbs Also See for Prorile Prima 30e:
Table of Contents

Advertisement

SITE REQUIREMENTS - Page 6
FIG. 4 FLUE LENGTHS

ELECTRICITY SUPPLY

A 240 volts 50Hz, single phase electricity supply fused to 3
amperes, must be provided in accordance with the latest
edition of the I.E.E. Wiring Regulations and any other local
regulations that may apply. The current rating of the wiring
to the boiler must exceed 3 amperes and have a cross
sectional area of at least 0.75mm
6500. Table 16.
Maximum working head
Minimum working head
Gas supply pressure
Maximum flow temperature
Electricity supply
Internal Fuse
Power Consumption
Gas supply connection
Appliance lift weight (mm)
Appliance weight installed
Water content
Flow/Return connections
REAR OR SIDE FLUEING
2
in accordance with BS
TECHNICAL DATA - Page 6
30.5m (l00ft)
150mm (6in)
20 mbar
0
82
C
240v-50Hz fused at 3A
Type T1A
80 Watts (excluding pump)
Rc. ½ (½ in BSP female)
30e, 40e, 50e & 60e Models
The supply to the boiler and its associated equipment
should be controlled by a 3A fused double pole switch
(having at least 3mm contact separation in both poles) so
that complete isolation from the supply can be achieved to
enable servicing work to be carried out in safety.
26.0kg (57.3Ibs)
37.1 kg (81 8lbs)
2.0 litre (0.44 gal)
22m copper
80e & l00e Models
33.5kg (73.871bs)
46.4kg (102.3lbs)
2.4 litre (0.53 gal)
28mm copper