Worcester GreenStar DanesMoor User And Care Manual page 8

Floor standing oil-fired condensing boiler conventional flue & room sealed flue 18-25kw
Table of Contents

Advertisement

1200mm
5mm*
600mm
Conventional flued appliances:
Minimum area of air inlet for combustion:
110cm² for 18/25kW appliances.
USER INSTRUCTIONS & CUSTOMER CARE GUIDE
8-716-106-255a (03.05)
380mm
300mm
5mm*
GENERAL INFORMATION
BOILER LOCATION:
This boiler is only suitable for installing internally
within a property at a suitable location onto a fixed
rigid non-combustible surface at least the same size
as the boiler and capable of supporting the boiler
weight.
The boiler is not suitable for external installation
unless a suitable enclosure is provided.
Roof space installations must fully conform to
BS5410 part 1 section 4.6.9
THIS BOILER IS NOT SUITABLE FOR ROOF
SPACE INSTALLATION.
VENTILATION:
Air vents must be functional at all times and the air
supply must not be restricted or contaminated.
The appliance clearances must meet the minimum
shown opposite for servicing and venting purposes.
* If this clearance is less than 75mm the flue 'knock-
out' panel sections must be removed to improve
air circulation and cooling.
Do not place clothes or objects to hinder the air
circulation required by the appliance.
Conventional flue appliances require an adequate
supply of fresh air which must be delivered to the
boiler for combustion purposes through a permanent
inlet, such as an air brick, into the area where the
boiler is situated.
GENERAL INFORMATION
5