Electrical Data - LG ATNC186ELAA Service Manual

Universal system air conditioner
Table of Contents

Advertisement

Electrical Data

Electrical Data
Nominal
Capacity
Indoor Unit
(Btu/hr)
ATNC186ELAA
ATNC186ELCA
ABNC186HLAA
AVNC186BLAA
18k
ATNH186ELAA
ATNH186ELCA
ABNH186HLAA
AVNH186BLAA
ATNC246FLAA
ATNC246FLCA
ABNC246HLAA
AVNC246BLAA
24k
ATNH246FLAA
ATNH246FLCA
ABNH246HLAA
AVNH246BLAA
ATNC306FLAA
ATNC306FLCA
ABNC306GLAA
AVNC306BLAA
30k
ATNH306FLAA
ATNH306FLCA
ABNH306GLAA
AVNH306BLAA
ATNC368DLAA
ATNC368DLCA
ABNC368GLAA
36k
ATNH368DLAA
ATNH368DLCA
ABNH368GLAA
ATNC488DLAA
ATNC488DLCA
ABNC488ELAA
48k
ATNH488DLAA
ATNH488DLCA
ABNH488ELAA
ATNC608DLAA
ATNC608DLCA
ABNC608ELAA
60k
ATNH608DLAA
ATNH608DLCA
ABNH608ELAA
NOTES :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x Max. RLA + other RLA + each FLA
MFA = 2.25 x Max. RLA + other RLA + each FLA
( Next lower standard fuse rating. Minimum 20A)
4. Select wire size based on the MCA
5. MFA is used to select the circuit breaker and ground fault circuit interrupter(each leakage circuit breaker).
6. RLA is based on the following conditions.
Indoor temperature : 27°CDB / 19.0°CWB(80.6°FDB / 66.2°FWB)
Outdoor temperature : 35°CDB(95°FDB)
54 Universal System Air Conditioner
Outdoor Unit
V-PH-Hz
AUUC186A/AB
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
AUUH186A/AB
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
AUUC246A/AB
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
AUUH246A/AB
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
AUUC306A/AB
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
AUUH306A/AB
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
AUUC368A/AB
380~415-3-50
380~415-3-50
380~415-3-50
AUUH368A/AB
380~415-3-50
380~415-3-50
380~415-3-50
AUUC488A/AB
380~415-3-50
380~415-3-50
380~415-3-50
AUUH488A/AB
380~415-3-50
380~415-3-50
380~415-3-50
AUUC608A/AB
380~415-3-50
380~415-3-50
380~415-3-50
AUUH608A/AB
380~415-3-50
380~415-3-50
380~415-3-50
OperatingVoltage
Compressor
Fan FLA Fan FLA
Minimum Maximum
RLA
7.1
32.3
7.1
7.8
8.1
6.9
32.3
6.9
7.4
7.7
9.7
9.7
10.1
198V
264V
10
9.6
9.6
9.9
10.1
11.4
11.4
11.9
12.1
11.8
11.8
12.2
12.3
4.9
4.9
5.2
4.9
4.9
5.2
6.5
6.5
342V
456V
6.8
6.5
6.5
6.8
6.9
6.9
7.9
6.9
6.9
7.9
Indoor Ooutdoor
LRA
MCA
1.0
0.7
10.6
1.0
10.6
1.2
11.6
0.3
11.1
1.0
0.7
10.3
1.0
10.3
1.2
11.1
0.3
10.6
62
0.7
0.7
13.6
0.7
13.6
1.2
14.5
0.4
13.6
62
0.7
0.7
13.4
0.7
13.4
1.2
14.2
0.4
13.7
68
0.9
0.7
15.8
0.9
15.8
1.7
17.3
0.5
16.3
68
0.9
0.7
16.3
0.9
16.3
1.7
17.6
0.5
16.6
47
1
0.9
8.1
1
8.1
1.8
9.2
47
1
0.9
8.1
1
8.1
1.8
9.2
63
2
1.6
11.8
2
11.8
3.8
13.9
63
2
1.6
11.8
2
11.8
3.8
13.9
81
2.3
1.6
12.7
2.3
12.7
3.8
15.3
81
2.3
1.6
12.7
2.3
12.7
3.8
15.3
Power
MFA
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25
25
25
20
20
20
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25

Hide quick links: