APPENDIX
t rinse interval
t concentrate
t min disposal
t max disposal
t maintenance
76
function:
Time after which a DISCONTINUOUS RINSE
process is started provided that the control
system was during that time in the operating
condition RINSE INTERVAL.
right of access: technician
possible setting: 0-99h (0h)
function:
Duration of a CONCENTRATE
DISPLACEMENT/FLUSH process at the end of
a PRODUCTION (TANK FULL active).
right of access: technician
possible setting: 0-99min (1 min)
funtion:
Minimum duration of a DISPOSAL process at the
beginning of a PRODUCTION. This is the
minimum time after which the unit passes to
PRODUCTION if the value drops below LIM.
right of access: technician
possible setting: 0-999s (5s)
Attention: the set value must be less than t max
disposal. (Pay attention to units)
function:
Maximum duration of a DISPOSAL process. This
is the maximum time after which the value has to
be below LIM, otherwise a failure message will be
given.
right of access: technician
possible setting: 1-99min (60 min)
Attention: the set value must be greater than
t min disposal (Pay attention to units!)
function:
Operating time (hour meter) after which a signal
is given that maintenance has to be carried out
(flashing OPERATION).
right of access: technician
possible setting: 0-999999h (3500h)
Attention: zero setting means that no
maintenance message is given.
WTC 600 LP / MP
Service Handbook 08.2004