Kärcher WaterClean 600 LP Operating Instructions Manual

Karcher water system user manual
Hide thumbs Also See for WaterClean 600 LP:

Advertisement

Quick Links

Operating Instructions

WATERCLEAN 600 LP / MP
BTA 5.960-505.0
ETL 5.970-054.0 (LP 400V)
5.970-055.0 (MP 400V)
5.970-156.0 (LP 230V)
5.970-157.0 (MP 230V)
A 2011201

Advertisement

Table of Contents
loading

Summary of Contents for Kärcher WaterClean 600 LP

  • Page 1: Operating Instructions

    Operating Instructions WATERCLEAN 600 LP / MP BTA 5.960-505.0 ETL 5.970-054.0 (LP 400V) 5.970-055.0 (MP 400V) 5.970-156.0 (LP 230V) 5.970-157.0 (MP 230V) A 2011201...
  • Page 2 Version 06/05 WTC 600 LP / MP...
  • Page 3: Table Of Contents

    WTC 600 LP / MP Contents Safety Notes...3 Intended Use ...3 Maintenance and Care ...4 Starting Operation ...4 3.1.1 Admission-pressure Unit ...4 3.1.2 Filling the Metering Stations ...4 3.1.3 Switching On the Equipment ...5 3.1.4 Operating Indicators ...5 During Operation ...5 3.2.1 Control and Corrective Action Intervals..5...
  • Page 4: Maintenance And Care

    • Shut the lid of the metering station. • Pull the mixing rod (28) out of the metering station to the stop and push back in again. Repeat this procedure for approx. 5 minutes until the chemical is completely mixed. WTC 600 LP / MP...
  • Page 5: Switching On The Equipment

    WTC 600 LP / MP If the metering container was com- pletely empty, the metering pump (29) may have possibly drawn in air. In this case, bleed the air from the pump as described in Section 3.2.3. 3.1.3 Switching On the Equipment •...
  • Page 6: During Operation

    No operational malfunctions detectable • Press the ADVANCE key button briefly; the display indicates the number of days and hours since the last regeneration. WTC 600 LP / MP In Case of Deviation Fill up; mixing chemi- cals, see Section 3.2.6 Bleed metering pump, see Section 3.2.3...
  • Page 7: Bleeding The Metering Pump

    WTC 600 LP / MP • After a while the indication moves back to the current time. 3.2.3 Bleeding the Metering Pump The metering pump must be bled when the pump has drawn in air (e. g., because the metering con- tainer is completely empty).
  • Page 8 • Shut the pressure control valve (14) in clock- wise direction in small steps until the drinking water amount in the viewing glass (42) has reached the set value. WTC 600 LP / MP...
  • Page 9: Mixing The Chemicals

    WTC 600 LP / MP Notice: The amount of concentrate will in- crease. This is correct. Observe the maximum pressure of 21 bar (MP) or 14 bar (LP) at the manometer (11)! • Repeat the adjustment steps, if required. The original drinking water amount may possibly not quite be reached.
  • Page 10: Switching Off The Equipment

    • Switch the main switch (20) to the “O” position; the equipment stops the drinking water produc- tion. WTC 600 LP / MP Switching Off the Equipment If the equipment is not operated for periods exceeding 14 days, it must be preserved by the Kärcher Service.
  • Page 11: Malfunctions

    WTC 600 LP / MP Malfunctions Malfunctions of the RO system are signaled with LEDs at the control panel (10) and indicated at the display. In case of a malfunction, the system is generally switched off and the drinking water production is interrupted.
  • Page 12: Technical Data

    System intake pressure Capacity range Maximum drinking water supply Dimensions: H x W x D WTC 600 LP/MP WTC 600 LP/MP - A WTC 600 LP/MP - AM Weight, in delivery condition WTC 600 LP/MP WTC 600 LP/MP - A...
  • Page 13: Eu Declaration Of Conformity

    WTC 600 LP / MP EU Declaration of Conformity We hereby declare that the equipment described below conforms to the relevant fundamental safety and health requirements of the appropriate EU Directive, both in its basic design and construction as well as in the version marketed by us.