C
I
OMPLETING THE
NSTALLATION
Fixing the Outdoor Unit in Position
'X'mm
Rubber leg
X
✴✴09✴✴
457
538
✴✴12/14✴✴
Checking and Testing Operations
14
E-
The outdoor unit must be installed on a rigid and stable base to
avoid any increase in the noise level and vibration, particularly if the
outdoor unit is to be installed close to a neighbour.
If it is to be installed in a location exposed to strong winds or at a height,
the unit must be fixed to an appropriate support (wall or ground).
1
Position the outdoor unit so that the air flow is directed towards the
outside, as indicated by the arrows on the top of the unit.
2
Attach the outdoor unit to the appropriate support using anchor bolts.
Y
254
3
If the outdoor unit is exposed to strong winds, install shield plates around
290
the outdoor unit, so that the fan can operate correctly.
➢
Certainly fix up its rubber leg in order to prevent its vibration
and noise.
To complete the installation, perform the following checks and tests to
ensure that the air conditioner is operating correctly.
1
Review all the following elements in the installation:
◆
Installation site strength
◆
Piping connection tightness to detect any gas leakages
◆
Connection wiring
◆
Heat-resistant insulation of the piping
◆
Drainage
◆
Earthing wire connection
◆
Correct operations (follow the steps below)
2
Press the
Result:
3
Press the
Result:
4
Air flow direction
button.
◆ The indicator lights on the indoor unit flash at half-second
intervals.
◆ While the indoor unit opens, the indoor unit fan runs to start.
button.
The outdoor unit operates in cooling mode as
following the room temperature.
Press the
button and check that the air flow
blades work properly.