4. Disassembly and Reassembly
4-2 Replacement of High Voltage Transformer (Continued)
3.
Remove the mounting bolts .
4.
Replace the High Voltage Transformer
5.
After replace, reconnect the leads correctly and firmly.
PRECAUTION
Servicemen should remove their watches whenever working close to or replacing the magnetron .
PRECAUTION
There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the
HIGHVOLTAGE TRANSFORMER secondary and filament terminals. It is extremely dangerous to work on
or near these circuits with the oven energized .
DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron.