4.

maintenanCe

The amount of use and the working environment should be taken into consideration
when planning the frequency of maintenance of the machine. Careful use and preventive
maintenance will help to ensure trouble-free operation.
Cables
Check the condition of welding and connection cables daily. Do not use faulty cables! Make
sure that the mains connection cables in use are safe and according to regulations! The
repair and mounting of mains connection cables should be carried out only by an authorized
electrician.
power source
Disconnect the plug of the power source from the mains socket before removing the cover
NOTE!
plate.
Check at least every 6 months (twice a year):
• Electric connections of the unit - clean the oxidized parts and tighten the loosened ones.
You must know correct tension torques before starting the repair of the joints.
NOTE!
• Clean the inner parts of the machine from dust and dirt e.g. with soft brush and vacuum
cleaner.
Do not use compressed air, there is a risk that dirt is packed even more tightly into gaps of
components!
Do not use pressure washing device!
Only authorized electrician shall carry out repairs to the machines.
regular maintenance
Kemppi service repair workshops make regular maintenance according to agreement.
The major points in the maintenance procedure are listed as follows:
• Cleaning of the machine
• Checking and maintenance of the welding tools
• Checking of connectors, switches and potentiometers
• Checking of electric connections
• Metering units checking
• Checking of mains cable and plug
• Damaged parts or parts in bad connection are replaced by new ones
• Maintenance testing. Operation and performance values of the equipment are checked,
and adjusted when necessary by means of test equipment.
4.1

dispOsal OF the maChine

Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic
equipment, and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and taken to an appropriate
environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional
collection centre, per the instructions of local authorities or a Kemppi representative. By
applying this European Directive you will improve the environment and human health.