6.2 Regulations Covering Stove Installation

When installed and operated as described in these instructions, the Escape 1800 wood
stove is suitable for use as a freestanding heater in residential installations. The Escape
1800 wood stove is not intended for installation in a sleeping room of a mobile home.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and
Equipment and the CSA C22.1 Canadian National Electrical Code are to be followed in the
absence of local code requirements. In the USA, the ANSI NFPA 211 Standard for
Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances and the ANSI NFPA 70
National Electrical Code are to be followed in the absence of local code requirements.
This stove must be connected to a chimney complying with the requirements for Type HT
chimneys in the Standard for Factory-Built Chimneys for Residential Type and Building
Heating Appliances, UL 103 and ULC S629 or to a code-approved masonry chimney with
a flue liner.
29