Changing the wire guide
If the wire guide is too worn or totally clogged, change it to a new one
according to the following instructions:
1.
2.
3.
4.
EN
5.
6.
7.
4.

DISPOSAL

Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical
and electronic equipment, and its implementation in accordance with
national law, electrical equipment that has reached the end of its life must
be collected separately and taken to an appropriate environmentally
responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit
to a regional collection centre, per the instructions of local authorities
or a Kemppi representative. By applying this European Directive you will
improve the environment and human health.
14
Disconnect the welding gun from the machine.
a. Disconnect the cable clamp of the gun's power cable by opening the
screws.
b. Disconnect the gun's power cable from the machine's pole.
c. Disconnect the connector of the trigger conductors from the machine.
d. Open the gun's mounting nut.
e. Extract the gun gently from the machine whereupon all parts come
through the front part's cable hole.
Open the mounting nut of the wire guide which exposes the end of the
wire guide.
Straighten the welding gun's cable and withdraw the wire guide from
the gun.
Push a new wire guide in to the gun. Make sure that the wire guide
enters all the way into the contact tip's adapter and that there is an
o-ring at the machine-end of the guide.
Tighten the wire guide in place with the mounting nut.
Cut the wire guide 2 mm from the mounting nut and file the sharp
edges of the cut round.
Reattach the gun in place and tighten the parts to spanner tightness.