Sharp R-953(SL)M Service Manual page 23

Microwave oven with grill and convection
Table of Contents

Advertisement

DESCRIPTION OF LSI
LSI(IXA034DR)
The I/O signal of the LSI(IXA034DR) are detailed in the following table.
Pin No.
Signal
22
INT1
23
INT0
24
CNVSS
25
RESET
26
P41
IN/OUT
27
P40
28
XIN
29
XOUT
30
VSS
31
P27
32
P26
33
P25
34
P24
35
P23
I/O
OUT
Terminal not used.
IN
Signal to synchronized LSI with commercial power source frequency(50Hz).
This is basic timing for time processing
of LSI.
IN
Connected to VC.
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily
set to "L" level the moment power is applied, at this time the LSI is reset. Thereafter
set at "H" level.
Memory (EEPROM) data input/output.
OUT
Memory (EEPROM) clock out.
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit
with respect to XIN terminal.
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of XOUT.
IN
Power source voltage: -5V.
VC voltage of power source circuit input.
OUT
Grill (TOP) heating element driving signal.
To turn on and off the grill heating
element relay (RY3). "L" level during
grill cooking, convection cooking or
dual cooking, "H" level otherwise.
The heater relay turns on and off
within a 48 second time base in
accordance with the special program
in LSI.
OUT
Convection heating element driving signal.
To turn on and off the relay (RY4). "L"
level during grill cooking, convection
cooking or dual cooking, "H" level
otherwise.
The heater relay turns on and off within
a 48 second time base in accordance
with the special program in LSI.
OUT
Oven lamp and turntable motor driving signal(Square Waveform : 50Hz).
To turn on and off shut-off relay (RY1).
The square waveform voltage is
delivered to the relay (RY1) driving
circuit.
OUT
Convection motor driving signal.
To turn on and off shut-off relay(RY7). "L"
level during convection or dual cooking "H"
level otherwise. (Relay RY7 does not turn on
at preheating mode.)
OUT
Fan motor driving signal.
To turn on and off the fan motor relay RY6. "L"
level during cooking, or for 5 minutes after grill
cooking or for a while after convection or dual
cooking. "H" level otherwise.
R-953/963M - 21
Description
20 msec.
Power output
100 %
90 %
80 %
70 %
60 %
50 %
40 %
30 %
20 %
10 %
Power output
100 %
90 %
80 %
70 %
60 %
50 %
40 %
30 %
20 %
10 %
20 msec.
During cooking
During
cooking
(Convection or dual cooking)
ON
ON
H : GND
L (-5V)
ON time
OFF time
48 sec.
0 sec.
44 sec.
4 sec.
40 sec.
8 sec.
36 sec.
12 sec.
32 sec.
16 sec.
26 sec.
22 sec.
22 sec.
26 sec.
16 sec.
32 sec.
12 sec.
36 sec.
8 sec.
40 sec.
ON time
OFF time
48 sec.
0 sec.
44 sec.
4 sec.
40 sec.
8 sec.
36 sec.
12 sec.
32 sec.
16 sec.
26 sec.
22 sec.
22 sec.
26 sec.
16 sec.
32 sec.
12 sec.
36 sec.
8 sec.
40 sec.
H
L
H.
GND
OFF
L
H.
GND
OFF
L
During cooking or for awhile after
grill convection or dual.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-953wmR-963slmR-963wm

Table of Contents