Report Commands:
Command:
+EB
Description:
Default:
Defined Values:
Report Commands:
Command:
+ESR
Description:
Report Commands:
Command:
+EFCS
Description:
Defined Values:
Report Commands:
Multi-Tech Systems, Inc. SocketModem MT5600SMI/MT5656SMI Reference Guide (S000306C)
Chapter 1 – AT Commands, S-Registers and Result Codes
+ES=3
Enable V.42 with Detection Phase originator. Disable V.80
Synchronous Access Mode originator.
+ES=,,2
Allow LAPM, MNP, or Normal Mode connection answerer.
Disable V.80 Synchronous Access Mode answerer.
+ES=3,,2
Enable V.42 with Detection Phase originator, allow LAPM,
MNP, or Normal Mode connection answer. Disable
Synchronous Access Mode originator and answerer.
+ES?
Reports the current values
Response: +ES: <orig_rqst>,<orig_fbk>,<ans_fbk>
Example: +ES: 3,0,2 For the default setting.
+ES=?
Reports supported range of parameter values
Response: +ES: (<orig_rqst> range),( <orig_fbk> range),
(<ans_fbk> range)
Example: +ES: (0-4,6,7),(0-4),(0-6,8,9)
Break Handling in Error Control Operation
This extended-format compound parameter controls the break handling in
V.42 operation. It accepts three numeric subparameters:
None
<break_selection>
Decimal number 0 specifying that break is to be
ignored, i.e., not signaled to remote DCE.
<timed>
Decimal number 0 specifying that any transmitted
V.42 L-SIGNAL will not indicate break signal length
<default_length>
Decimal number 0 specifying that break is not
delivered to the DTE.
+EB?
Reports current or selected values
Response: +EB:
<break_selection>,<timed>,<default_length><CR>
Example: +EB: 0,0,0 For default settings.
+EB=?
Reports supported range of parameter values
Response: +EB: (<break_selection> range),(<timed> range),
(default_length> range)
Example: +EB: (0),(0),(0)
Selective Reject
This extended-format numeric parameter controls the use of the selective
reject (SREJ) option in V.42.
Decimal number 0 specifying that SREJ is not used.
+ESR?
Reports Current or Selected Values:
Response: +ESR: <value>
Example: +ESR: 0 For default setting
+ESR=?
Reports Supported Range of Parameter Values
Response: +ESR: (<value>)
Example: +ESR: (0)
32-bit Frame Check Sequence
This extended-format numeric parameter controls the use of the 16-bit or
32-bit frame check sequence (FCS) option in V.42.
<value> Decimal number 0 specifying the use of the 16-bit FCS specified
in V.42.
+EFCS?
Current or Selected Values:
Response: +EFCS: <value>
Example: +EFCS: 0 For default setting.
+EFCS=? Reporting Supported Range of Parameter Values
Response: +EFCS: (<value> range)
Example: +EFCS: (0)