Connecting The Piping - LG FLEX MULTI SPLIT Installation Instructions Manual

Flex multi split dual zone & tri-zone
Hide thumbs Also See for FLEX MULTI SPLIT:
Table of Contents

Advertisement

Check
1. Compare the flared work with the figure by.
2. If a flared section is defective, cut it off and
do flaring work again.

Connecting the Piping

Indoor
1. Prepare the indoor unit's piping and drain hose for installation through the wall.
2. Remove the plastic tubing retainer(see the
illustration by) and pull the tubing and drain
hose away from chassis.
3. Replace only the plastic tubing holder 1, not
the holder 2 in the original position.
For right rear piping
1. Route the indoor tubing and the drain hose in
the direction of rear right.
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy
connection later.
3. Tape the tubing, drain hose, and the
connecting cable. Be sure that the drain hose
is located at the lowest side of the bundle.
Locating at the uper side can cause drain pan
to overflow inside the unit.
If the drain hose is routed inside the room,
insulate the hose with an insulation material*
so that dripping from "sweating"(condensation)
will not damage furniture or floors.
*Foamed polyethylene or equivalent is
recommended.
Flaring Work and Connection of Piping
Smooth all round
Inside is shiny without scratches
Inclined
Even length
all round
Drain hose
Tape
Connecting
pipe
Drain hose
Connecting cable
= Improper flaring =
Surface
Cracked Uneven
damaged
thickness
Drain hose
Loop
Gas side piping
Connecting
cable
Liquid side piping
Drain hose
Installation Manual 13