Step 3. INSTALL THE VENT SYSTEM
General Information
These instructions should be used as a
guideline and do not supersede local codes
in any way. Install vent according to local
codes, these instructions, the current National
Fuel Gas Code (ANSI-Z223.) in the USA or
the current standards of CAN/CSA-B49.
in Canada.
Clearance in accordance with local installa-
tion codes and the requirements of the gas
supplier.
Dégagement conforme aux codes d'installation
locaux et aux exigences du foumisseunde
gaz.
Use only approved venting components.
See Approved Vent Components on
Page 2.
These fireplaces must be vented directly
to the outside.
The vent system may not service multiple
appliances, and must never be connected to a
flue serving a solid fuel burning appliance. The
vent pipe is tested to be run inside an enclosing
wall (such as a chase). There is no requirement
for inspection openings in the enclosing wall at
any of the joints in the vent pipe.
Installation of Vent Restrictor
A vent restrictor may be needed with this
appliance. The restrictor is installed in the
appliance top flue outlet as shown in Figure
14, either before adding vent, from above, or
after installation of vent from below, within the
firebox. The restrictor is self securing through
a positive friction fit.
Determine the venting for the appliance. If the
vent run will include at least 8 feet of vertical
rise, then install the restrictor in the appliance
collar before connecting any vent (Refer to
Figure 14 ). Place the restrictor inside the ap-
pliance vent collar and press in place.
Note: The restrictor is included within the
firebox.
Select Venting System - Horizontal or Vertical
With the appliance secured in framing, determine
vent routing and identify the exterior termina-
tion location. The following sections describe
vertical (roof) and horizontal (exterior wall)
vent applications. Refer to the section relating
to your installation. A list of approved venting
components is shown on Pages 32 and 33.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Vent Restrictor Installation
(Top Vent)
A vent restrictor may be needed when vertical-
ly terminating the vent system above the roof
(when using the appliance top vent), install
vent restrictor in the top vent of the fireplace
outlet on all MLDVT series models. If needed,
install the restrictor orientated as shown,
either from inside or outside the unit,in the
inner fireplace collar.
Restrictor
Inner
Fireplace
Appliance Top
Collar
Vent Outlet
Figure 14