Horizon Fitness 24VF Installation Operation & Maintenance

Vent free, adjustable from 14,000 btu/h to 18,000 btu/h

Advertisement

Quick Links

Horizon
WarnInG:
If the information in this manual
is not following exactly, a fire or
explosion may result causing
property damage, personal injury,
or loss of life.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; Do not use any phone in your
building.
Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
F o r
Y o u r
SaFeTY:
Do not store or use gasoline
or other flammable vapors
and liquids in the vicinity of
this or any other appliance.
Installation
Operation &
Maintenance
24VF
Vent Free
Gas Fireplace
Adjustable from
14,000 BTU/H to
18,000 BTU/H
Check local codes and read all
instructions prior to installation.
Installer: Leave this manual
with the appliance.
Consumer: Leave this man-
ual for future reference.
This is an unvented
gas-fired heater. It
uses air (oxygen) from
the room in which it
is installed. Provisions
for adequate combus-
tion and ventilation
air must be provided.
refer to page 3.
359

Advertisement

Table of Contents
loading

Summary of Contents for Horizon Fitness 24VF

  • Page 1 Installation Horizon Operation & Maintenance 24VF Vent Free Gas Fireplace Adjustable from 14,000 BTU/H to 18,000 BTU/H Check local codes and read all instructions prior to installation.  Installer: Leave this manual with the appliance. Consumer: Leave this man-  ual for future reference.
  • Page 2: Table Of Contents

    The 24VF includes an adjustible burner from 18,000 BTU/H to 14,000 Safety, as well as efficiency of operation, must be considered when BTU/H and a 2 piece ceramic fibre logset. The 24VF is rated for selecting the fireplace location. Try to select a location that does not Propane with a maximum input of 18,000 BTU/H and a minimum interfere with room traffic and has adequate ventilation.
  • Page 3: Vent Free Installation

    Horizon 24VF Gas Fireplace Installation Clearances Framing These clearances apply to all dimensions except the framed opening, where the clearance to combustibles is 0 cm. The 24VF clearances to combustible materials are: Top 8 cm Back 0 cm * When sheetrock is...
  • Page 4: Installing The Gasline

    Installing The Gas Line surface temperatures and should stay away to avoid burns or 1. The gas line must be installed before finishing the 24VF Fireplace. Propane Gas requires a minimum inlet gas supply pressure of 35 mbar W.C. & a manifold pressure of 24 mbar Provision must also Note: After gas line is connected, each appliance connection, be made for a 1/8"...
  • Page 5: Facing

    Horizon 24VF Gas Fireplace Installation Finishing Around the Fireplace Association, when painting the fireplace surrounds, to select and ap- Combustible mantels and mouldings may be safely installed over the ply a quality Alkyd sealer prior to the applying of latex paints. This is...
  • Page 6: Removing And Installing The Screen Door

    Installing the Logs: Take care when removing the screen door, and ensure that the fire- The 24VF is supplied with a two-piece fibre logset. The logset is very place has been properly cooled before handling the screen door. fragile and must be handled very carefully.
  • Page 7: Safety Considerations

    Horizon 24VF Gas Fireplace SAFETY CONSIDERATIONS: DO NOT START THE FIREPLACE BEFORE READING THIS SECTION: Any changes made to this heater or the controls may be dangerous and may cause serious injury or death. In the case that changes were made, warranty will be voided.
  • Page 8: Operation

    Horizon 24VF Gas Fireplace Operating Instructions For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lit by hand. When partment.
  • Page 9: Maintenance

    Burner Adjustment Doors and logs can get very hot. Handle only when The 24VF is equipped with an adjustable burner, allowing you to raise or lower the flames. General Light the pilot as per the lighting instructions.
  • Page 10: Gas Control Valve

    Horizon 24VF Gas Fireplace Maintenance Cleaning the Oxygen Gas Control Valve Depletion Sensor (ODS) The most common problem with the vent-free fireplace is a dirty ODS.The symptoms of a dirty ODS can be any of the following: A. Pilot will not stay lit.
  • Page 11: Troubleshooting Guide

    Horizon 24VF Gas Fireplace Troubleshooting Guide All troubleshooting repairs must be performed by a certified gas technician. You can only determine problems and causes. If you cannot oper- ate the stove by trying the routine procedures described in this manual, DO NOT attempt to fix the fireplace yourself.
  • Page 12 Horizon 24VF Gas Fireplace Notes Page 1 Part No. XG0138...
  • Page 13: Warranty

    Horizon 24VF Gas Fireplace Warranty The Warranty Montigo DelRay Corp. warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and fibre logs.
  • Page 14 Horizon Installed and Serviced by: XG0138 - 122006 Canadian Heating Products 27342 Gloucester Way, Langley, BC...

Table of Contents