10. Standard8 REC L Level Adjustment (VC-215 board)

CCD-TR315E/TR415E/TR425E
CCD-TRV16E/TRV26E/TRV27E/TRV27EP
Set the recording levels of the REC AFM signal and REC ATF sig-
nal. If the level is too low, the audio S/N will deteriorated, tracking
will not be stable, or SP/LP will not be discriminated properly. If
too high, color beets will be produced on the self-recording/play-
back image.
Mode
VTR recording (SP mode)
Signal
No signal
Pin !º of CN910 (REC RF)
Measurement Point
Measuring Instrument
Oscilloscope
(20MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
5B to 64
Specified Value
A = 9.3±0.5mV
Connection:
1) Remove C085 (0.01µF, Pin !§ of IC202).
Note: After completing "REC L Level Adjustment" and "REC C
Current Adjustment", replace C085 with new parts (1-162-
970-11 CERAMIC CHIP 0.01µF 10% 25V).
Adjusting method:
1) Insert Srandrd8 MP tape.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to "1". (Refer to "3. Bit value discrimination"
of "3-1-8. Service mode").
4) Select page: D, address: 15, after memorizing the data , set the
bit value of bit7 to "0".
5) Set to recording mode. (Use the wireless remote commander
of 8mm VCR, or connect Pin 6 of CN935 of DD-117 board
and GND with 4.7kΩ registor for a second.)
4.7kΩ registor : 1-249-425-11
6) Insert Srandrd8 MP tape, set to recording mode.
7) Select page: 0, address: 01, and set data: 01.
8) Select page: F, address: 5B, set data: FF, and press the PAUSE
button of the adjusting remote commander.
9) Select page: F, address: 65, set data: 00, and press the PAUSE
button of the adjusting remote commander.
10) Select page: F, address: 5C, change the data and set the REC
AFM signal level (A) to the specified value.
11) Press the PAUSE button of the adjusting remote commander.
12) Select page: F, address: 5C, read the data (D
13) Calculate the adjustment data (hexadecimal) from the follow-
ing equations (hexadecimal calculation), and input each adjust-
ment address. (Refer to Table 5-1-2. Hexadecimal-Decimal
conversion Table.)
Address: 5B
D
5B
Address: 5D
D
5D
Address: 5E
D
5E
Address: 5F
D
5F
Address: 60
D
60
Address: 61
D
61
Address: 62
D
62
Note: After setting each data, be sure to press the PAUSE button
of the adjusting remote commander.
).
5C
= D
5C
= D
5C
= D
5C
= D
5C
= D
5C
= D
5C
= D
5C
14) Write the following data in page: F, address: 63 to 64.
Address
Data
63
64
Note: After setting each data, be sure to press the PAUSE button
of the adjusting remote commander.
15) Select page: 0, address: 01, and set data: 00.
16) Perform "REC C Current Adjustment".
17) Select page: 0, address: 01, and set data: 01.
18) Select page: D, address: 14, and set the data memorized at step
3) of "Preparations only for the model without REC switch".
19) Press the PAUSE button of the adjusting remote commander.
20) Select page: D, address: 15, and set the data memorized.
21) Press the PAUSE button of the adjusting remote commander.
22) Select page: 0, address: 01, and set data: 00.