Bolt-In Heating Element, Thermostat & Eco / 110 Vac Trouble Shooting Wiring Schematic; 110Vac Troubleshooting - Atwood Pilot 6 Gallon User Manual

Table of Contents

Advertisement

BOLT-IN
Heating Element, Thermostat & ECO
Temperature
Adjustment Dial
Early model water heaters with 110 VAC heating
capacity used a bolt-on heating element and a one
piece thermostat/E.C.O..
This 110 VAC system has an adjustable rectangular
thermostat that is surface mounted to the inner tank
and retained by a steel clip. The temperature settings
are HI, MEDIUM, and LOW. If the thermostat is
making unobstructed contact with the aluminum tank
and it is set to the HI position, it should heat the water
to 130° F. It will take longer to heat a tank of water on
electric than gas.
The heating element was changed in 1996 from
1500W to 1400W bringing the amperage draw down
to 12.7 amps and allowing more cushion for the
15 amp circuit breaker that is normally placed in line.
This change adds a few minutes to the heating time.
There are 110 VAC aftermarket conversion kits being
offered by distributors in which the heating element is
screwed into the tank where the drain plug is located.
We do not offer such a kit. Our kit includes the tank
with the 110 VAC components already installed in it.
110VAC Trouble-Shooting
UP
Ground Lead
ECO
Common Lead
Re-Set
Button
In the case where the 110VAC portion of the water
heater is not heating water, the following diagnostic
steps and repairs should be investigated:
Turn POWER OFF to the appliance before
removing junction box cover.
Perform the following steps with POWER ON to
water heater.
1. Verify switch-A is in ON position.
2. Insure there is 110VAC to the unit (measure
Perform the following steps with POWER OFF to
water heater.
3. ECO Re-set Button-D should be depressed.
4. Check for continuity between screw-B and screw-
5. If water is insufficiently hot, check ECO /
6. Verify a good wire connection between thermostat
7. There should be continuity between heating
8. Check for continuity between element screw-G
9. Verify ground connection.
NOTE: Heating element can be operated on an empty
tank for a limited period of time before it self-destructs.
11
Wiring Schematic
Switch
Hot Lead
BLACK
( 1 )-BLACK
( 3 )-GREEN
Ground
BLACK
( 2 )-WHITE
Element
voltage across the black and white lead to the
appliance with POWER ON). If none, trace wiring
back and make appropriate wire repair.
C of thermostat. If none, replace thermostat.
Thermostat-E is on high.
screw-C and heating element screw-G. Correct if
necessary.
element screw-G and screw-F. If none, element is
bad and should be replaced. Do not over-tighten
self-tapping screws when installing new element.
and flange of element. If there is, element has
shorted. Element should be replaced.
Manual Reset
High Temperature
Limit Switch
Fixed Thermostat

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents