All unused slots must contain a filler panel. A filler panel unit consists of an
aluminum board mounted with a blank faceplate. You can remove and
replace these units with the power on. Filler panels are inserted into all
unused slots from the front of the chassis and serve three primary functions:
Maintain the cooling integrity of the system by occupying the space
where a module would normally be seated, thereby directing air flow to
where it is needed most. It is especially important to install filler panels in
all unused slots when stacking chassis.
Keep dust and other debris out of the chassis slot.
Ensure FCC compliance.
You will need a #1 Phillips screwdriver to complete the following procedures.
Be sure to save all filler panels for possible re-configuration of the system.

Removing a Filler Panel

To remove a filler panel:
1. Ensure that you are properly grounded by wearing an ESD protective
device.
2. Loosen the two captive screws (shown in Figure 4-2) that secure the unit
in the chassis.
3. Unseat the panel by moving the ejector levers to the outward position, as
shown in Figure 4-2.
4. Grasp both ejector levers and gently slide the unit straight out from the
chassis.