Before Calling Service Guide for Common Problems
Caution: Disconnect Power Supply Prior to Attempting Any Service!
Problem
Cooler not running.
Condensing unit on cooler
runs for prolonged period or
continuously.
Cooler temperature too high.
Cooler is noisy.
Cooler is freezing product.
Cooler compressor will not
start-hums and trips on
overload protector.
Lid will not close.
Possible Cause
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Power cord unplugged.
Thermostat in "OFF" position.
Improper voltage supplied to cooler.
(voltage does not match data plate)
Thermostat set too high.
Excessive amount of warm product. Allow adequate time for product to cool down.
Prolonged lid openings or (lids) ajar. Make sure lid is closed. Avoid prolonged lid openings.
Dirty condenser coil.
Improper air flow around condensing
unit.
Evaporator coil blocked with ice.
Thermostat set too high.
Poor circulation in cooler.
Excessive amount of warm product. Allow adequate time for product to cool down.
Prolonged lid openings or (lids) ajar. Make sure lid is closed. Avoid prolonged lid openings.
Dirty condenser coil.
Insufficient clearance around cooler
or excessively high ambient temperature.
Evaporator coil blocked with ice.
Part(s) loose.
Tubing vibrating.
Thermostat is set too low.
Cooler overloaded with product.
Dirty condenser coil.
Excessive heat generated from
equipment nearby.
Voltage to cooler too high or too low. Check and correct supply voltage.
Tracks guiding lid(s) not clean.
VDW WIRING DIAGRAM
115V/60Hz/1Ph
Remedy
Plug in cord.
Turn thermostat clockwise and set temperature.
Correct supply voltage. (remove extension cords or other
equipment on circuit, etc.)
Set thermostat to lower temperature.
Clean the condenser coil.
Insure adequate air space, relocate away from heat
generating equipment, direct sunlight, or direct path of air
conditioning or heating ducts.
Turn unit off and allow coil to defrost. Make sure thermostat
is not set too cold and that lid(s) seal properly.
Set thermostat to lower temperature.
Re-arrange product to allow proper air circulation.
Clean the condenser coil.
Insure adequate air space, relocate away from heat generating
equipment (ovens, fryers, etc.) and out of direct sunlight.
Turn unit off and allow coil to defrost. Make sure thermostat
is not set too cold and that lid(s) sealed properly.
Locate and tighten loose part(s).
Insure tubing is free from contact with other tubing or components.
Set thermostat to higher temperature.
Remove or rearrange product.
Clean the condenser coil.
Relocate cooler, or adjacent heat generating equipment.
Clean tracks.