Download Print this page

Victory VDW-24-4 Manual page 2

Deep well horizontal bottle coolers
Hide thumbs Also See for VDW-24-4:

Advertisement

IMPORTANT! CONDENSER MAINTENANCE
To keep your cooler running efficiently and trouble free,
clean the condenser coil and condensate drain pan at
least once every three months or more often. The
condensate drain pan should be emptied after all interior
cleanings and beverage spills.
1. Remove beverages and close lid(s). Pull cooler forward
and remove power cord from receptacle.
2. For condenser coil access, remove two screws from
front grill. Use both hands to carefully pull grill forward
and out from cabinet. "See pictures below"
3. Remove condensate drain pan by pulling the silver tab.
Clean pan and reinstall. "See pictures below"
4. To properly clean the condenser coil, compressor-motor
and related parts:
a) Use a vacuum cleaner with proper brush attachments.
b) Use compressed air.
c) Use a soft bristled brush in a "rolling motion" to get
dirt and grime on the brush. Do not push dirt and
grime into the coil ,and do not flatten coil fins.
Grill
"Front Grill Removal"
6. After cleaning, reassemble cooler and properly restore
power.
7. Return beverages when cooler has reached working
temperature.
Temperature Control
Cooler temperature controls are adjusted at the factory
before shipping to maintain an average temperature of
36°F (2.2°C) and should not need adjustment.
The temperature control is located inside the cooler at the
upper right hand side. A flat head screwdriver can be used
to make adjustments, if needed.
"Temp Control Location"
-or-
Coil
"Condenser Coil Cleaning"
"Adjusting Temperature"
Divider Installation
1. Discontinue power to the cooler! (*note: fans must not
be operating during divider installation)
2. Place spring on the middle rod of divider bar that will be
placed at the rear of cooler.
3. Put divider in cooler and mount the middle rod with
spring in desired mounting hole at the rear of cabinet.
4. Place top and bottom divider rods without springs straight
across into the front mounting holes.
5. Repeat the procedure for additional dividers.
6. Restore power to cabinet after all dividers are placed.
Drain
Pan
Technical Service & Replacement Parts
Victory Refrigeration strives to provide excellent customer
service along with quality equipment. To help us better
Refer to the guide on the next page of this document prior
to calling for technical assistance.
Technical information and replacement parts support can
also be obtained via website. Just go to www.victory-
refrig.com and click on the customer service link.
Common Replacement Parts
(1) 10830401- Grill Assembly, Front or Rear
(2) 10831501- Lid Assembly, VDW-24 (Complete)
(3) 10831601- Lid Assembly, VDW-36 (Complete)
(4) 10831701- Lid Assembly, VDW-50 (Complete)
(5) 10831801- Lid Assembly, VDW-65 (Complete)
(6) 10831901- Lid Assembly, VDW-95 (Complete)
(7) 10833201- Bottle Opener Assembly (Complete)
(8) 50893701- Cover, Bottle Opener
(9) 50893801- Base, Bottle Opener
(10) 50894001- Bottle Opener
(11) 50894901- Spring, 3" Retainer Divider (VDW-36,50,65 & 95)
(12) 50894902- Spring, 1.5" Retainer Divider (VDW-24)
(13) 50894701- Divider,VDW-36,50,65&95
(14) 50894801- Divider,VDW-36,50,65&95 (*mounts to fan)
(15) 50895001- Divider,VDW-24
(16) 50895101- Divider,VDW-24 (*mounts to fan)
assist you, a serial number and/or model
number must be provided when contacting
the technical service or parts department.
The data plate is located inside the cooler
on the upper left wall. All serial numbers are
recorded and kept indefinitely.

Advertisement

loading

This manual is also suitable for:

Vdw-50-18Vdw-37-12Vdw-95-38Vdw-65-24