INSTALLATION

Remote Station Wiring

An individual 4-wire cable (IW-4UL) must be connected from
each remote station or remote control location to the master
station's terminals.
• Maximum station wire length: 150 feet .
• Maximum total of IW-4UL cable per system: 600 feet.
• Never bundle cables between master station and remote
stations/door speakers together. Cables that are bundled
together will reduce intercom/monitor volume and cause
squealing/noise.
• Never use 4-wire telephone cable or other 4-wire cable.
Use only NuTone IW-4UL flat ribbon cable. The use of
telephone cable or other 4-wire cable will reduce intercom
monitor/volume and cause squealing/noise.
IMPORTANT: NuTone cannot be responsible for improper
system operation that results from interference generated
by light dimmers, fluorescent lighting fixtures, and similar
electrical products. Such interference must be corrected at
the source.
To help reduce this interference, all wiring connected to the
master must be placed at least 12 inches from any A.C.
power wiring.
Maximum Number of Remote
Stations
The master station will accommodate a maximum of (6) remote
stations/remote controls/volume controls and 3 door speakers.
IMPORTANT: Never use standard 8 ohm stereo speakers or
the master station will be damaged.
Mounting the Optional Chime
Module in the Master Station
Panel
Refer to Figure 2
To install the chime module, first position the master face down on a
soft cloth to prevent surface damage.
1. Align the optional IA-28 or IA-29 chime module with the
mounting bracket located in the master station panel.
2. Apply firm, even pressure to each side of the chime module
until the module snaps into place.
3. Fasten the chime module with the one (1) screw supplied with
the module
4. Plug the 4 pin connecter from the chime module into the
connecter on the master panel (be sure the connector is
aligned correctly with the master station connector).
5. Connection from the chime pushbuttons will be made after the
master station's panel has been mounted to the rough-in frame.
MODEL IA-29 ONLY
1. Locate the chime selector switch mounting bracket in the master
station's panel.
2. Remove and set aside the chime selector switch retaining
screw.
3. Remove and discard the square foam pads on the chime
selector switch PC board connected to the chime module.
4. Slide the PC board into the mounting bracket on the master
station's panel.
5. Fasten the chime selector switch PC board with the retaining
screw previously removed from the master station panel.
RETAINING
SCREW
(IA-29)
CHIME SELECTOR
SWITCH
(IA-29)